Beam characteristic of P.E collimators Add-on multileaf collimator

  • سال انتشار: 1397
  • محل انتشار: مجله فیزیک پزشکی ایران، دوره: 15، شماره: 0
  • کد COI اختصاصی: JR_IJMP-15-0_449
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 74
دانلود فایل این مقاله

نویسندگان

Seyed Aliasghar Rohani

Department of Medical Physics, Tehran University of Medical Science, Tehran, Iran

Ghazale Graily

Department of Medical Physics, Tehran University of Medical Science, Tehran, Iran

Seied Rabi Mahdavi

Radiation biology research center & medical Physics department, faculty of medicine, Iran university of medical Science, Tehran, Iran

Ahmad Mostaar

Department of Medical Physics, School of Medicine, Shahid Beheshti University of Medical Science, Tehran, Iran

چکیده

Introduction:    Multileaf collimators (MLCs) are computer-controlled devices which are Useful and cost-effective tools for conformal therapy and intensity modulation radiotherapy (IMRT). Nowadays MLCs are important and standard configuration of the new medical linear accelerators which are substitute of conventional Blocks and has eliminated the difficulties of working with blocks. MLCs are available from many manufacturers and their designs differ in the way they couple with conventional jaws, number and width of leaves and in their physical and dosimetric characteristics, well understanding on the mechanics and dosimetric characteristics of MLC is the basic task of medical physicist.   Materials and Methods:  In this study some mechanical and dosimetric characteristics of a P.E. Collimators Add-On MLC which is installed on VARIAN CLINAC ۲۱۰۰ C/D are presented. Scatter factors (Sc, Sp, Scp), central axis depth dose and beam profiles were measured before and after installation of MLC. mechanical and Leaf Leakages for ۶MV and ۱۸MV beams were measured with Gafchromic EBT۳ films.   Results:  radiation and light fields were match below the ۲mm acceptable level based on AAPM reports. Average leaf leakage was noted ۱.۷۹% for ۶MV and ۱.۹۸% for ۱۸MV beams, respectively. No significant differences were found in beam profiles, collimator (Sc), phantom (Sp) and total (Sc, p) scatter factors after MLC installation. The percent depth dose data for all fields and both beam energies were within ۱.۶ % of the original data.     Conclusion:  Based on the Mechanical and dosimetric results which have been achieved from our different standard tests, we found no significant differences between before and after MLC installation Values on Clinac ۲۱۰۰ C/D Varian LINAC.

کلیدواژه ها

Multileaf Collimator, Picket Fence Test, Leaf Transmission

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.