Fireproofing Effects of I Section Beam-to-CHS Column Connections Behaviour in Oil Platform Decks at Elevated Temperature

  • سال انتشار: 1391
  • محل انتشار: سومین کنفرانس ملی زلزله و سازه
  • کد COI اختصاصی: CESCM03_015
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 1672
دانلود فایل این مقاله

نویسندگان

Seyed Ahmad Hosseini

PhD. candidate of Civil Engineering Dept. K.N.Toosi University, Tehran,

Mostafa Zeinoddini

Associate Prof of Civil Engineering, K.N.Toosi University, Tehran, Iran

Mohammad reza Bahaari

Associate Prof of Civil Engineering, Tehran University, Tehran, Iran

چکیده

Beam-to-column connections have been found to be of great significance in influencing structural behavior at ambient and elevated temperatures. Observations from full-scale fire tests and damaged structures confirm that connections have a considerable effect on the stability time of structural components in fire. One type of such connections is the connections between 1-shape beam and pipe shape columns in oil platform decks. Considering the high probability of fire in oil platforms, study of the behavior ofthese connections at elevated temperatures is of importance. Therefore, 7 experimental tests have been conducted on this connection type to investigate their fire-resistance capacity

کلیدواژه ها

elevated-temperature behavior, fire, experimental study, fireproofing, beam-to-pipe column connection, oil platforms

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.