Synthesis and identification of meta-(۴-bromobenzyloxy) benzaldehyde thiosemicarbazone (MBBOTSC) as novel ligand for cadmium extraction by ultrasound assisteddispersive-ionic liquid-liquid micro extraction method

  • سال انتشار: 1400
  • محل انتشار: فصلنامه روش های تجزیه در شیمی محیط زیست، دوره: 4، شماره: 4
  • کد COI اختصاصی: JR_AMECJ-4-4_006
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 64
دانلود فایل این مقاله

نویسندگان

Abdolreza Hassanzadeh

Department of Medicinal Chemistry, Faculty of Pharmacy, Kerman University of Medical Sciences, Kerman, Iran

Bagher Amirheidari

Department of Pharmaceutical Biotechnology, Faculty of Pharmacy, Kerman University of Medical Sciences, Kerman, Iran

Ahmad Salarifar

Environmental Engineering, Faculty of Natural Resources, Islamic Azad University, Bandar Abbas Branch, Iran

Ali Asadipour

Department of Medicinal Chemistry, Faculty of Pharmacy, Kerman University of Medical Sciences, Kerman, Iran

چکیده

In this research, meta-(۴-bromobenzyloxy) benzaldehyde thiosemicarbazone (MBBOTSC) as a novel ligand was synthesized from the reaction between meta-(۴-bromobenzyloxy) benzaldehyde and thiosemicarbazide under basic condition in water and ethanol as solvents. Ligand has the ability to chelate ions and therefore, it was used to form a complex and extract ions. So, the cadmium ions in water and wastewater samples were separated based on MBBOTSC by ultrasound assisted-dispersive-ionic liquid-liquid microextractionmethod (USA-D-ILLME) before determination by AT-F-AAS.The MBBOTSC ligand was added to the mixture of the ionic liquid/acetone(IL/AC, [OMIM][PF۶]) and then injected by syringe to ۵۰ mL of water samples at pH ۶-۷.The sample was put into the ultrasonic accessory for ۵ minutes, after complexation (Ligand-Cd; RS…Cd….RS), the water sample was centrifuged for ۳ min for phase separation.Due to complexation and back-extraction of Cd in liquid phase,the amount of Cd ions in the water samples was determined by AT-F-AAS after dilution eluent (۰.۵ M, HNO۳) with DW up to ۱ mL.In optimized conditions, the Linear ranges and LOD for ۵۰ mL of water samples were obtained ۱-۳۶μg L-۱and ۰.۳μg L-۱, respectively (Mean RSD= ۱.۲۶%). The validation results were successfully achieved by spiking real samples and using electrothermalatomic absorption spectrometry (ET-AAS).

کلیدواژه ها

Cadmium, Meta-(۴-bromobenzyloxy) benzaldehyde thiosemicarbazone, Ligand, Synthesis, Metal extraction, Ultrasound assisted-dispersive-ionic liquid-liquid microextraction

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.