Separation and determination of lithium and manganese ions in healthy humans and multiple sclerosis patients based on nanographene oxide by ultrasound assisted-dispersive -micro solid-phase extraction

  • سال انتشار: 1400
  • محل انتشار: فصلنامه روش های تجزیه در شیمی محیط زیست، دوره: 4، شماره: 4
  • کد COI اختصاصی: JR_AMECJ-4-4_001
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 41
دانلود فایل این مقاله

نویسندگان

Seyed Majid Nabipour Haghighi

Department of Medical Nanotechnology, Faculty of Advanced Sciences and Technology, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran

Negar Motakef Kazemi

Department of Medical Nanotechnology, Faculty of Advanced Sciences and Technology, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran

چکیده

Lithium regulates the concentration of nitric oxide in the human body and a high dose of nitric oxide causes multiple sclerosis (MS). Also, the amount of manganese in the cerebrospinal fluid alters the metabolic reactions associated with MS. In this study, the mixture of the ammonium pyrrolidine dithiocarbonate (APDC), the hydrophobic ionic liquid [HMIM][PF۶] and acetone coated on the surface of graphene oxide nanoparticles (GONPs) and used for separation Li and Mn in human samples by ultrasound assisted-dispersive-ionic liquid-micro-solid phase extraction technique (USA-DIL-μ-SPE) at pH ۶.۰. After extraction and back-extraction, the amount of lithium and manganese in the blood, serum and urine samples was determined by the flame and the graphite furnace atomic absorption spectroscopy (F-AAS, GF-AAS), respectively. By optimizing parameters, the LOD, Linear ranges (LR) and preconcentration factor (PF) for Li and Mn ions were obtained (۰.۰۳ mg L-۱, ۰.۲۵ μg L-۱), (۰.۱-۰.۴ mg L-۱, ۰.۰۸-۱.۵ μg L-۱) and ۱۰, respectively (%RSD< ۵). The capacity adsorption of APDC/IL/GONPs and GONPs was achieved (۱۴۸.۵ mg g-۱, ۱۲۲.۳ mg g-۱) and (۴۱.۳ mg g-۱, ۳۳.۷ mg g-۱) for Li and Mn ions in a static system, respectively. This method was successfully validated by spiking samples and certified reference materials (CRM).

کلیدواژه ها

Lithium, Manganese, Human samples, Multiple sclerosis patients, Nano graphene oxide, Ultrasound assisted-dispersive-microsolid phase extraction

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.