Reusable and sustainable graphene oxide/metal–organic framework-۷۴/Fe۳O۴/polytyramine nanocomposite for simultaneous trace level quantification of five fluoroquinolones in egg samples by high performance liquid chromatography

  • سال انتشار: 1400
  • محل انتشار: فصلنامه روش های تجزیه در شیمی محیط زیست، دوره: 4، شماره: 2
  • کد COI اختصاصی: JR_AMECJ-4-2_002
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 112
دانلود فایل این مقاله

نویسندگان

Fatemeh Pourbahman

Department of Applied Chemistry, Faculty of Science, South Tehran Branch, Islamic Azad University, Tehran, Iran

Mohsen Zeeb

Department of Applied Chemistry, Faculty of Science, South Tehran Branch, Islamic Azad University, Tehran, Iran

Amirhossein Monzavi

Department of Polymer and Textile Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran

Zahra Khodadadi

Department of Applied Chemistry, Faculty of Science, South Tehran Branch, Islamic Azad University, Tehran, Iran

چکیده

A nanohybrid material termed graphene oxide/metal-organic framework-۷۴/Fe۳O۴/polytyramine (GO/MOF-۷۴/Fe۳O۴/PTy) was fabricated and applied in magnetic dispersive micro-solid phase extraction (MD-μ-SPE) coupled with high performance liquid chromatography (HPLC) for simultaneous determination of fluoroquinolones compounds including, ofloxacin, ciprofloxacin, lomefloxacin, enrofloxacin and sperfloxacin in egg samples. The GO/MOF-۷۴/Fe۳O۴/PTy nanocomposite was fabricated through an in situ synthesis of MOF-۷۴ in the presence of magnetic GO and followed with an oxidative polymerization of tyramine using horsedish peroxide (HRP) enzyme. The modifier agents improved the merits of the nanoporous sorbent. Extraction protocols based on GO/MOF nanocomposites have various benefit such as, the high stability, the tunable porosity, the fast mast transfer and reasonable enrichment factor. The fabricated material was characterized via energy dispersive x-ray analysis (EDX), the scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), and the x-ray diffraction (XRD). The calibration curves revealed linearity (۰.۹۹۹۲ ≤ r۲ ≤ ۰.۹۹۹۷) in the ranges of ۱.۰-۴۷۵.۰, ۰.۵-۳۵۰.۰, ۰.۵-۳۵۰.۰, ۰.۵-۳۷۵.۰ and ۱.۵-۳۰۰.۰ ng mL-۱ with limit of detections (LODs, S/N=۳) of ۰.۳, ۰.۱, ۰.۲, ۰.۱ and ۰.۴ ng mL-۱ for ofloxacin, ciprofloxacin, lomefloxacin, enrofloxacin and sperfloxacin, respectively. The intra-assay (≤۷.۷%, n = ۹) and inter-assay (≤۷.۰%, n = ۹) precisions along with accuracy less than ۹.۰% showed the reliability of the method.

کلیدواژه ها

Magnetic dispersive micro-solid phase extraction, Metal–organic framework, Graphene oxide, Polytyramine, Fluoroquinolones

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.