Photodegradation of the Antibiotic Penicillin G in the Aqueous Solution using UV-A Radiation

  • سال انتشار: 1392
  • محل انتشار: مجله علوم پزشکی ایران، دوره: 1، شماره: 3
  • کد COI اختصاصی: JR_JHES-1-3_006
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 146
دانلود فایل این مقاله

نویسندگان

Mansooreh Dehghani

Department of Environmental Health Engineering, School of Health

Mohammad Ahmadi

Department of Environmental Health Engineering, School of Health

Simin Nasseri

Department of Environmental Health Engineering, School of Health

چکیده

Background and purpose: Highly consumption of antibiotics and their entrance into the environment has increased concerns all over the world. These compounds enter to the environment through an incomplete metabolism and a considerable amount of them cannot be removed using usual waste filtration systems. Therefore, the present study aimed to investigate the feasibility of using ultraviolet radiation (UV-A) to remove penicillin G (PENG) from aqueous phase and determining its removal efficiency. Materials and Methods: The experiments were carried out in the batch mode. The samples were assessed in a ۲-liter reactor. In order to investigate the effect of UV-A radiation on the removal rate of antibiotic penicillin G (PENG), the following parameters were studied. Three concentration levels of PENG antibiotic (۱۰,۲۵,and ۴۵ mg/l) were exposed to UV-A at three pH levels (۳,۷,۱۱) and were evaluated at four reaction times (۳۰,۶۰,۹۰, and ۱۲۰ min). Antibiotic penicillin G (PENG) was determined using HPLC instrument (Waters YL۹۱۰۰,USA) and results analyzed using factorial design software. Results: The finding demonstrated that antibiotic removal rate increased by decreasing pH and decreasing the initial concentration of antibiotic and increasing contact time. The maximum rate of penicillin G removal occurred in acidic pH (pH=۳) is as much as ۳۸%. All of the variables in the process have been statistically significant effect (p< ۰.۰۰۱). Conclusion: Results showed that by reducing the pH, increasing contact time and reducing the antibiotic concentration, the removal rate increases. In conclusion, photodegradation process using UV-A may enhance the rate of penicillin G degradation in polluted water and could be used as a complementary step for other chemical and biological processes to remove penicillin G from the aqueous solution. Therefore, UV-A process in conjugate with the other processes is an appropriate method for reducing antibiotic penicillin G in polluted water resources.

کلیدواژه ها

Antibiotic, Penicillin G, UV-A Radiation, Photodegradation, Removal, Aqueous Solution

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.