Effects of the longitudinal chains on thermal performance of a double pipe heat exchanger, An Experimental Effort

  • سال انتشار: 1402
  • محل انتشار: بیستمین کنفرانس دینامیک شاره ها
  • کد COI اختصاصی: CFD20_101
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 183
دانلود فایل این مقاله

نویسندگان

Mohammad Jafari

Assistant Professor, Mechanical Engineering Department, Lorestan University, Iran

چکیده

The effects of a number of longitudinal chains soldered on the inner tube of a double pipe heat exchanger on its thermal performance are investigated experimentally. The chains have been made of a copper wire with ۱mm diameter. Each circle of the chain has ۳ mm internal diameter. The heat exchanger has an inner copper tube with ۱۶ mm outer diameter and ۱mm thickness when the outer pipe has ۴۰ mm inner diameter. The study was carried out when the Reynolds number of the hot fluid flow passing in the inner tube was ۴۰۰۰ when the Reynolds number of cold fluid passing through the annulus area were changed from ۳۰۰۰ to ۶۰۰۰. The results showed that the usage of the longitudinal chains leads to a noticeable growth in the overall heat transfer of the heat exchanger from ۱۰ to ۴۰ %. On other side, the results also represented an increase of the pressure loss in the outer tube, resulting an increase in the friction factor from ۸ to ۳۵ % based on the Reynolds number and number of the used chains.

کلیدواژه ها

Double Pipe Heat Exchanger, Longitudinal Chain, Thermal Performance

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.