Effects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer

  • سال انتشار: 1395
  • محل انتشار: گفتمان پژوهش دامپزشکی، دوره: 7، شماره: 4
  • کد COI اختصاصی: JR_VRFAN-7-4_002
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 155
دانلود فایل این مقاله

نویسندگان

Labrini Vasileiou Athanasiou

Department of Medicine, Faculty of Veterinary Medicine, University of Thessaly, Karditsa, Greece

Zoe Polizopoulou

Diagnostic Laboratory, Faculty of Veterinary Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece

Maria Rafaela Kalafati

Department of Medicine, Faculty of Veterinary Medicine, University of Thessaly, Karditsa, Greece

George Ntararas

Department of Medicine, Faculty of Veterinary Medicine, University of Thessaly, Karditsa, Greece

Vasileios Kontos

National School of Public Health, Department of Veterinary Public Health, Athens, Greece

چکیده

To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of ۳۰ clinically normal male adult beagle dogs. Each sample was separated in ۲ aliquots, of which one was stored in ambient temperature (۲۵ ˚C) and the other one was refrigerated (۲ to ۴ ˚C). Complete blood counts were performed in ۱, ۲.۵, ۵, ۱۲, ۲۴, ۳۶ and ۶۰ hr post-sampling for each aliquot of every sample using a flow cytometer. Packed cell volume values remained stable in the samples kept in room temperature (RT), whereas a significant increase was noted in the refrigerated ones ۲۴ hr post-sampling. Statistically significant increases in red blood cell counts were noted after ۲۴hr in the samples stored in ۲ to ۴ ˚C and after ۱۲ hr in those kept in RT. No significant changes were observed in haemoglobin concentration. A significant decrease was evident only ۶۰ hr post-sampling for the white blood cells kept in RT, but not for those kept in ۲ to ۴ ˚C. Platelet counts significantly decreased after ۲۴ hr in the refrigerated aliquots and after ۵ hr in those kept in RT. The results of this study indicate that storage of blood samples for up to ۲۴ hr in ۲ to ۴ ˚C is associated with the least artifactual changes.

کلیدواژه ها

Complete blood count, Dog, Hematology, stability, Temperature

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.