Effect of influent load fluctuation on the efficiency of vertical constructed wetlands treating dairy farm wastewater

  • سال انتشار: 1402
  • محل انتشار: فصلنامه پیشرفت ها در فناوری محیط زیست، دوره: 9، شماره: 3
  • کد COI اختصاصی: JR_AET-9-3_005
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 129
دانلود فایل این مقاله

نویسندگان

Pradeep Sharma

Department of Environmental Science, Graphic Era (Deemed to be) University, Dehradun, Uttarakhand, India

Anju Rani

Department of Microbiology, Graphic Era (Deemed to be) University, Dehradun, Uttarakhand, India

Deepa Minakshi

Department of Environmental Science, Graphic Era (Deemed to be) University, Dehradun, Uttarakhand, India

Piyush Malaviya

Department of Environmental Science, University of Jammu, Jammu and Kashmir, India

چکیده

Three vertical sub-surface flow (VSSF) constructed wetland (CW) systems (CW-۱, CW-۲ and CW-۳) filled with different filter media, each ۴ m۲ in area, planted with Arundo donax was operated for ۴ years for treating dairy farm wastewater. The vertical CW systems received high fluctuations in influent concentration and loads i.e. BOD (۲۶ to ۶۱۹ mg L-۱ and ۱.۵ to ۳۴ g m-۲ d-۱), TSS (۱۶۵ to ۶۴۳ mg L-۱ and ۹.۱ to ۲۴ g m-۲ d-۱), TP (۱۶ to ۴۹.۹ mg L-۱ and ۱.۲ to ۲.۷ g m-۲ d-۱) and NH۴-N (۲۴.۵ to ۷۶.۲ mg L-۱ and ۱.۳ to ۴.۲ g m-۲ d-۱) during the assessment period. Average annual removal rates showed fluctuations in removal of BOD (۷۰.۵ to ۹۲.۹%), TSS (۸۲.۵ to ۹۷.۵%), TP (۵۱.۱ to ۹۱.۹%) and NH۴-N (۳۴.۶ to ۶۹%). This shows that the removal of BOD is very sensitive to inlet load fluctuations in CWs. High inlet loads may confine good nitrification that affects ammonium-nitrogen removal while TP removal rate reduced when inlet TP loads reduced. The average concentration of the pollutants (BOD, TSS, TP and NH۴-N) in the treated effluent showed noticeable decrease: ۴۳.۴ to ۱۶.۱ mg L-۱ for BOD; ۴۳.۳ to ۱۱.۷ mg L-۱ for TSS; ۱۷.۹ to ۳.۱ mg L-۱ for TP and ۳۳.۲ to ۲۲.۷ mg L-۱ for NH۴-N. Thus from the outcomes of the current study, it can be concluded that the VSSF CW system may provide promising outcomes despite there is fluctuations in the influent loads.

کلیدواژه ها

Vertical sub-surface flow constructed wetland, influent loads, dairy farm wastewater, Organic matter, BOD

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.