Stirred tank reactor with dual impeller Rushton turbine for application of wastewater treatment - Process optimization and CFD simulation

  • سال انتشار: 1402
  • محل انتشار: فصلنامه پیشرفت ها در فناوری محیط زیست، دوره: 9، شماره: 3
  • کد COI اختصاصی: JR_AET-9-3_002
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 137
دانلود فایل این مقاله

نویسندگان

Shivanand Teli

Chemical Engineering Department, GF’s Gharda Institute of Technology, Khed, India

Sunil Kulkarni

Chemical Engineering Department, GF’s Gharda Institute of Technology, Khed, India

چکیده

The treatment of industrial wastewater by economical and efficient methods is being explored to improve treatment efficiency and costs. Wastewater treatment via biological methods to reduce carbonaceous matter is common in the form of an activated sludge process (ASP). In the current work, the aerobic decomposition of waste was carried out in a reactor with constant stirring with a Rushton type turbine. The optimum values of the flow rate of air were obtained for two reactor impeller configurations for better waste degradation. The extent of degradation in the stirred tank reactor was studied for different values of impeller clearances. Two configurations, C۱ and C۲, were investigated. It was observed that under a continuous air supply for ۳۶ hours, the impeller configuration C۲ provided ۸۰% degradation compared to ۷۴.۴ % for C۱. Increased values of superficial gas velocity (UG) and impeller speed resulted in decreased degradation due to shear stress on microorganisms for two impeller configurations. The hydrodynamic study confirmed that the impeller configuration C۱ required less power consumption than C۲ for the same operating condition. The k-epsilon turbulent model and the population balance model were used in combination. The models were validated with the experimental results of the hydrodynamic parameters for the values of operating parameters over a considerable range. The forecasting of mass transfer coefficients from different models was compared with practically determined values for the two configurations of impeller positions in the tank.

کلیدواژه ها

Biological treatment, Optimization, small scale industrial wastewater, coefficient, Configurations hydrodynamics, Fluid dynamics

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.