Identification of Extracellular Vesicles Derived from Plasma Using MALDI-TOF MS: Influence of Operating Conditions
- سال انتشار: 1402
- محل انتشار: فصلنامه گزارش های زیست فناوری کاربردی، دوره: 10، شماره: 3
- کد COI اختصاصی: JR_JABR-10-3_007
- زبان مقاله: انگلیسی
- تعداد مشاهده: 205
نویسندگان
Department of Genetic Engineering, School of Bioengineering, SRM Institute of Science and Technology, Kattankulathur, Chengalpattu-۶۰۳۲۰۳, India
Department of Paediatric Neurology, Apollo Children’s Hospital, Thousand lights, Chennai-۶۰۰۰۰۶, India
Department of Biological Sciences, SRM University – Andrapradesh, ۵۲۲۲۴۰, India
School of Bioengineering, SRM Institute of Science and Technology, Kattankulathur, Chengalpattu-۶۰۳۲۰۳, India
Department of Genetic Engineering, School of Bioengineering, SRM Institute of Science and Technology, Kattankulathur, Chengalpattu-۶۰۳۲۰۳, India
چکیده
Introduction: Extracellular vesicles (EVs) are biomolecular messengers secreted by all types of cells. It passes messages through molecular cargoes such as proteins, nucleic acids, and lipids from the parent cell to the target cell. EVs derived from the plasma are used for minimally invasive biopsy and as a possible biomarker to monitor the progression and severity of the disease. In this study, the matrix-assisted laser desorption and ionization-time of flight mass spectrometry approach was used to characterize and study the protein fingerprint region of plasma-derived extracellular vesicles.Materials and Methods: At first, ۳ ml of blood sample was collected from five boys of ۵-۱۰ years in sodium citrate tubes, and the samples were centrifuged within an hour to extract plasma. The total exosome isolation (TEI) method was used to obtain high-yield plasma-derived EVs, and the EVs were stored at -۸۰ °C for further analysis. The isolated intact EVs were mixed with an optimal concentration of sinapinic acid matrix (۲۰ mg/ml) in a ۱:۱ ratio for fingerprint analysis using matrix-assisted laser desorption/ionization–time of flight mass spectrometry (MALDI-TOF MS). We found that the following operational conditions yielded good and high-resolution spectra: broad mass range (۲۰۰۰- ۲۰۰۰۰ m/z), detector gain (۳۰x), and laser shot (۵۰, ۳۰۰, and ۱۰۰۰) with ۱۰۰% laser intensity. The obtained MALDI TOF spectral peaks of plasma EVs (pEVs) matched the reported biomarkers.Results: Based on the analyses, we improved the crucial experimental conditions and identified five distinct peaks at m/z = ۳۳۱۵, ۶۶۳۰, ۹۴۲۱, ۸۸۷۵, and ۸۹۱۷. C۴A, C۳, and apolipoproteins A-II, C-I, C-II, and C-III were identified by comparing MALDI-TOF MS data with existing reports.Conclusions: MALDI-TOF MS-based EV analysis can support the development of protein biomarker screening tools for early diagnosis.کلیدواژه ها
Extracellular vesicles, Matrix-Assisted Laser Desorption-Ionization Mass Spectrometry, Peptide Mapping, Characterizationاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.