Drill- and suction generated noise levels in mastoid surgery
- سال انتشار: 1387
- محل انتشار: مجله علمی گوش و حلق و بینی ایران، دوره: 19، شماره: 50
- کد COI اختصاصی: JR_IJOTO-19-50_005
- زبان مقاله: انگلیسی
- تعداد مشاهده: 229
نویسندگان
Ahwaz, PO Box ۱۱۹۸-۶۱۵۵۵
Member of the scientific board of Audiology Department, Iran University of Medical Sciences.
Professor, member of the scientific staff of the Ear, Throat and Nose Department, Iran University of Medical Sciences
Professor, member of the scientific staff of the Ear, Throat and Nose Department, Iran University of Medical Sciences
چکیده
Introduction: It has been recognized that noise levels generated during ear surgery may cause sensorineural hearing loss. However, there is a controversy about the main factor that may cause such hearing threshold alternations: drilling, suction or both of them. The purpose of this investigation was to measure the air-conduction noise levels generated by common drills, burrs and suction irrigators in mastoid surgery.Materials and Methods: Our evaluations were carried out in two states: isolated temporal bones (cadavers) and intraoperative recordings. Preliminary drillings were made on ۱۰ cadavers, and intensity and frequency analysis of common diamond and cutting burrs were performed. Then, the noise levels generated by drilling, suction irrigation and simultaneous drilling & suction irrigation were measured from ۱۵ patients under radical modified mastoidectomy. Data were analyzed by SPSS ۱۱ software and ۰.۰۵ value was regard as significant level.Results: The average noise levels of drilling ranged from ۸۳ to ۹۵ dB SPL, varying with burr used. Cutting burrs were found to be up to more intense than diamond burrs. Mean suction irrigation noise levels ranged from ۷۷.۴۵ to ۷۸.۶۵ dB SPL. The average of "intraoperative drilling" and "simultaneous drilling and suction irrigation" generated noise levels were ۸۷.۱۴ and ۸۶.۲۶ dB SPL, respectively. The comparison of resultant noise levels between cadaver and under operation situations was not statistically significant.Conclusion: Our results showed that the main factor contributing the highest noise level is drilling which is predominately apparent in cutting burrs. Exposure to these noise levels may account for shifts in the hearing thresholds.کلیدواژه ها
Noise level, Drilling, Suction, Mastoid surgeryاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.