Twisted Bundle Heat Exchangers Performance Evaluation by CFD

  • سال انتشار: 1391
  • محل انتشار: چهاردهمین کنگره ملی مهندسی شیمی ایران
  • کد COI اختصاصی: NICEC14_322
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 1125
دانلود فایل این مقاله

نویسندگان

Gh. S. Jahanmir

Chemical and Petroleum Engineering Department, Sharif University of Technology, Azadi Ave

F farhadi

چکیده

Shell and tube heat exchanger with single twisted tube bundle in five different twist angles, are studied using computational fluid dynamics (CFD) method and compared to the conventional design withsingle segmental baffles. Effect of shell-side nozzles configurations on heat exchanger performance is studied as well. Heat transfer rate and pressure drop are the main issues investigated in the paper. The results show that, for the same shell-side flow rate, the heat transfer coefficient of heat exchangerwith twisted tube bundle is lower than that of the heat exchanger with segmental baffles while shellside pressure drop of the former is even much lower than that of the latter. The comparison of heat transfer rate per unit pressure drop versus shell-side mass flow rate shows that heat exchanger withtwisted tube bundle in both cases of vertical and tangential shell-side nozzles, have significant performance advantages over the segmental baffled heat exchanger. The performance of twisted tube bundle heat exchanger does not change dramatically with altering the tube bundle twist angle.

کلیدواژه ها

Shell and Tube Heat Exchanger, Twisted Tube Bundle, Computational Fluid Dynamics, Heat Transfer, Pressure Drop

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.