A Monte Carlo study on quantification of scattering and edge penetration in a breast-dedicated SPECT scanner with lofthole collimation

  • سال انتشار: 1402
  • محل انتشار: مجله پزشکی هسته ای ایران، دوره: 31، شماره: 2
  • کد COI اختصاصی: JR_IRJNM-31-2_002
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 104
دانلود فایل این مقاله

نویسندگان

Maryam Saed

Department of Physics, Faculty of Science, University of Guilan, Rasht, Iran

Alireza Sadremomtaz

Department of Physics, Faculty of Science, University of Guilan, Rasht, Iran

Hojjat Mahani

Radiation Applications Research School, Nuclear Science and Technology Research Institute, Tehran, Iran

چکیده

Introduction: Quantitative accuracy in SPECT is mainly affected by collimator penetration and scattering, particularly for high-energy imaging. Lofthole collimation offers superior performance in terms of penetration and scattering.Methods: In this research, the GATE Monte Carlo simulator was exploited to calculate edge penetration and scattering in the lofthole collimator using an in-air and in-phantom point source of Tc-۹۹m and I-۱۲۳. The performance of the lofthole was then compared to that of a pinhole. Both lofthole and pinhole collimators were assumed to have the same geometry including an aperture diameter of ۳.۰۴ mm and an opening angle of ۷۵°. Furthermore, the angular distribution of the scattering and penetration were investigated for a multi-lofthole collimator.Results: The results show that penetration, scattering, and sensitivity are all a function of the photon energy. The penetration and scattering of the pinhole are about ۴% higher than that of the lofthole collimator, for Tc-۹۹m SPECT. Compared to the Tc-۹۹m, I-۱۲۳ SPECT suffers from approximately ۱.۵- and ۱.۴۲-fold higher penetration and scatter fractions, respectively, for lofthole aperture. Moreover, the lofthole collimator presents a higher sensitivity compared with the pinhole (۰.۰۳۰ versus ۰.۰۲۳ for the Tc-۹۹m SPECT). In addition, the findings exhibit a reduction in sensitivity by increasing the photon incidence angle. Both scattering and penetration fractions illustrate a decreasing trend across the angle of incidence.Conclusion: Compared to pinhole, the lofthole offers superior performance in terms of scattering and penetration for both low- and high-energy SPECT imaging.

کلیدواژه ها

Penetration, Scattering, SPECT, Collimator, Monte Carlo Simulation, Lofthole

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.