Speckle Tracking Accuracy Enhancement by Temporal Super‑Resolution of Three‑Dimensional Echocardiography Images

  • سال انتشار: 1400
  • محل انتشار: مجله سیگنالها و سنسورهای پزشکی، دوره: 11، شماره: 3
  • کد COI اختصاصی: JR_JMSI-11-3_003
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 219
دانلود فایل این مقاله

نویسندگان

Mohammad Jalali

Department of Biomedical Engineering, Iran University of Science and Technology, Tehran, Iran

Hamid Behnam

Department of Biomedical Engineering, Iran University of Science and Technology, Tehran, Iran

چکیده

Background: Speckle tracking has always been a challenging issue in echocardiography images due to the lowcontrast and noisy nature of ultrasonic imaging modality. While in ultrasound imaging, framerate is limited by image size and sound speed in tissue, speckle tracking results get worse inthree‑dimensional imaging due to its lower frame rate. Therefore, numerous techniques have beenreported to overcome this limitation and enhance tracking accuracy. Methods: In this work, we have proposedto increase the frame rate temporally for a sequence of three‑dimensional (۳D) echocardiographyframes to make tracking more accurate. To increase the number of frames, cubic B‑spline is usedto interpolate between intensity variation time curves extracted from every single voxel in theimage during the cardiac cycle. We have shown that the frame rate increase will result in trackingaccuracy improvement. Results: To prove the efficiency of the proposed method, numerical evaluation metricsfor tracking are reported to make a comparison between high temporal resolution sequences andlow temporal resolution sequences. Anatomical affine optical flow is selected as the state‑of‑the‑artspeckle tracking method, and a ۳D echocardiography dataset is used to evaluate the proposedmethod. Conclusion: Results show that it is beneficial for speckle tracking to perform on temporally condensedframes rather than ordinary clinical ۳D echocardiography images. Normalized mean enhancementvalues for mean absolute error, Hausdorff distance, and Dice index for all cases and all frames are۰.۴۴ ± ۰.۰۹, ۰.۴۲± ۰.۰۹, and ۰.۳۶ ± ۰.۰۶, respectively.

کلیدواژه ها

Cubic B‑spline interpolation, speckle tracking, temporal super‑resolution, three‑dimensional echocardiography

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.