Evaluation of Asymmetry in Right and Left Eyes of Normal Individuals Using Extracted Features from Optical Coherence Tomography and Fundus Images

  • سال انتشار: 1400
  • محل انتشار: مجله سیگنالها و سنسورهای پزشکی، دوره: 11، شماره: 1
  • کد COI اختصاصی: JR_JMSI-11-1_002
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 92
دانلود فایل این مقاله

نویسندگان

Tahereh Mahmudi

Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran- Medical Image and Signal Processing Research Center, School of Advanced Technologies in Medicine, Isfahan University of Medical Sc

Raheleh Kafieh

Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran

Hossein Rabbani

Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran

Mohammad-Reza Akhlaghi

Department of Ophthalmology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran

چکیده

Background: Asymmetry analysis of retinal layers in right and left eyes can be a valuable tool for early diagnoses of retinal diseases. To determine the limits of the normal interocular asymmetry in retinal layers around macula, thickness measurements are obtained with optical coherence tomography (OCT). Methods: For this purpose, after segmentation of intraretinal layer in threedimensional OCT data and calculating the midmacular point, the TM of each layer is obtained in ۹ sectors in concentric circles around the macula. To compare corresponding sectors in the right and left eyes, the TMs of the left and right images are registered by alignment of retinal raphe (i.e. diskfovea axes). Since the retinal raphe of macular OCTs is not calculable due to limited region size, the TMs are registered by first aligning corresponding retinal raphe of fundus images and then registration of the OCTs to aligned fundus images. To analyze the asymmetry in each retinal layer, the mean and standard deviation of thickness in ۹ sectors of ۱۱ layers are calculated in ۵۰ normal individuals. Results: The results demonstrate that some sectors of retinal layers have signifcant asymmetry with P < ۰.۰۵ in normal population. In this base, the tolerance limits for normal individuals are calculated. Conclusion: This article shows that normal population does not have identical retinal information in both eyes, and without considering this reality, normal asymmetry in information gathered from both eyes might be interpreted as retinal disorders.

کلیدواژه ها

Alignment, asymmetry analysis, fundus images, optical coherence tomography