PLATELETS FOR DENOISING OF SPECT IMAGES: PHANTOM AND PATIENT STUDY

  • سال انتشار: 1384
  • محل انتشار: دوازدهمین کنفرانس مهندسی پزشکی ایران
  • کد COI اختصاصی: ICBME12_008
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 1199
دانلود فایل این مقاله

نویسندگان

N Alibabaei

Tehran University of Medical Sciences(TUMS), School of Medicine, Department of Medical Physics and Biomedical Engineering,Tehran,Iran

A Takavar

Tehran University of Medical Sciences(TUMS), School of Medicine, Department of Medical Physics and Biomedical Engineering,Tehran,Iran

N Riyahi-Alam

Tehran University of Medical Sciences(TUMS), School of Medicine, Department of Medical Physics and Biomedical Engineering,Tehran,Iran

M Sohrabi

Research Institute for Nuclear Medicine, Shariati Hospital,Tehran,Iran

چکیده

In this study the evaluation of a Platelet-based Maximum Penalized Likelihood Estimation (MPLE) for denoising SPECT images was performed and compared with other denoising methods such as Wavelets or Butterworth filteration. Platelet-based MPLE factorization as a multiscale decomposition approach has been already proposed for better edges and surfaces representation due to Poisson noise and inherent smoothness of this kind of images .We applied this approach on both simulated and real SPECT images.For Nema phantom images, the measured noise levels before (2.1732) and after denoising with Platelet-based MPLE approach (0.1399) was found.In patient study for 32 cardiac SPECT images, the difference between noise level and SNR before and after applying approach were (Mb=3.7607, SNRb=9.7762, Ma=0.7374, SNRa=41.0848). Thus the Coefficient Variance (C.V) of SNR values for denoised images with this algorithm incompare with filteration with Butterwoth filter, 145/33% was found.For 32 brain SPECT imagesvalues this Coefficient Variance,196/17% was found.Our results showed that Platelet-based MPLE is a useful method for denoising SPECT images considering better homogenous image,improvements in SNR, better radioactive uptake in target organ and reduction of interfering activity from background radiation in compare with that of other conventional denoising methods.

کلیدواژه ها

Denoising, Image Approximation, SPECT, Platelets, MPLE