Measurement and simulation of the effective annual dose and radiation hazards of Jooshan hot spring in Kerman province

  • سال انتشار: 1402
  • محل انتشار: فصلنامه فیزیک و مهندسی پرتو، دوره: 4، شماره: 3
  • کد COI اختصاصی: JR_RPE-4-3_006
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 101
دانلود فایل این مقاله

نویسندگان

Mahmoud Abdoulahpour

Department of Physics, Payame Noor University (PNU), Tehran, Iran

Mohammad Reza Rezaie

Department of Nuclear Engineering, Faculty of Sciences and Modern Technologies, Graduate University of Advanced Technology, Kerman, Iran

Saeed Mohammadi

Department of Physics, Payame Noor University (PNU), Tehran, Iran

چکیده

Hot springs are known as one of the hydrotherapy centers in the world and have been welcomed due to their healing properties. Due to the presence of radon and radioactive elements in hot spring sediments, water and soil, these components are radioactive. So far, radiation hazards and the annual effective dose of hot spring components in the body organs have not been investigated in Iran. The purpose of this study was to calculate the amount of  U-۲۳۸, Cs-۱۳۷, Th-۲۳۲, and K-۴۰ elements in soil, water, and sediments of Jooshan hot springs in the Kerman region. The presence of these elements causes radiation hazards and an effective annual dose in people who use these hot springs. In addition to the healing properties of hot springs, the high amount of radiation hazard and effective annual dose may cause cancer risk. Experimental results with CsI(Tl) detector showed that the total activities of these elements in soil, water, and sediments of Jooshan hot spring were ۹۵.۲۶±۹.۷۶, ۵۲.۸۶±۷.۲۷, and ۵۱.۶۱±۷.۱۸ Bq.kg-۱ respectively. The Jooshan hot spring's radiation hazards were calculated using activity measurement of the radioactive elements in soil, water, and sediments which was less than the permission level. The result of the Monte Carlo simulation with the MCNPX code showed that the effective annual dose of sediment, water, and radon in Jooshan hot spring are ۵.۴۳E-۰۶, ۳.۰۰×۱۰-۳ and ۱.۱۶×۱۰-۱ mSv.year-۱ respectively, which is less than effective annual dose (۵ mSv.year-۱). The maximum time for treatment by hot spring water is considered equal to one year.

کلیدواژه ها

Hot springs, effective annual dose, Radioactive elements, Activity, sediments, Jooshan, Kerman

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.