Combined Analysis of Breast Morphometry, Compression and Volumetric Breast Density: Valuable Input to Improve Mammography Screening Using International Bench Marking

  • سال انتشار: 1402
  • محل انتشار: مجله فیزیک پزشکی ایران، دوره: 20، شماره: 3
  • کد COI اختصاصی: JR_IJMP-20-3_001
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 178
دانلود فایل این مقاله

نویسندگان

Youssef Bouzekraoui

Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Sciences and Health Technologies, Settat, Morocco

Hilde Bosmans

KU Leuven, Faculty of Medicine, Department of Imaging and Pathology, Medical Physics and Quality Assessment, Belgium.

Lesley cockmartin

Universitair Ziekenhuis Leuven

Mauro campoleoni

Fondazione IRCCS Ca&#۰۳۹; Granda Ospedale Maggiore Policlinico: MILANO, Italy

sanae Douama

Laboratory of high energy physics Modelisation Simulation, Faculty of Sciences, University Mohammed V, Rabat, Morocco

imane Ou-saada

Laboratory of high energy physics Modelisation Simulation, Faculty of Sciences, University Mohammed V, Rabat, Morocco.

FARIDA BENTAYEB

Departement of Physics, Laboratory of High Energy Physics, Modelling and Simulation, Faculty of Science, Mohammed V Agdal University, Rabat, Kingdom of Morocco

چکیده

Introduction: The aim of this study was to select parameters from a combined analysis of breast compression, breast morphometry and volumetric breast density, telling about the overall quality of breast positioning, and to apply these investigations on a Moroccan population at the start of new breast cancer screening activities. The study found that compression force in mammography varies greatly and has no specific limit. The researchers attempted to find correlations between compression force and mammographic factors to establish a range of values for standardized compression in mammography.Material and Methods: The study was carried out in a university hospital, a candidate screening center, provided with new technology equipment, qualified staff and doctors of different specialties. Image acquisition was procured on a FFDM Siemens Inspiration system for ۲۵۰ patients in diagnostic mammography and all patients’ information was collected. The data about dose, the compression force and the thickness of the compressed breast were obtained directly from the DICOM header information, applying Volpara Density software.Results: The results show a correlation between compression force and breast density. The volume of breast tissue compared to the total volume of the breast (VBD) decreased with increasing compressed breast thickness (CBT) and age. The mean VBD was ۹.۳% ± ۶%, the compression force was ۷۱±۱۵ N and the CBT was ۵۳±۱۱ mm.Conclusion: The global analysis and comparison of mammographic parameters showed good similarity between Moroccan and the previous studies population. The mammographic techniques can therefore be used to Moroccan screening programs.

کلیدواژه ها

Mammographies, Digital Mammography, Mammographic Breast Density

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.