Dosimetric Comparative Study between Single and Dual Isocenter Stereotactic Body Radiotherapy Plans in Treatment of Multiple Lesions Non-Small Cell Lung Cancer Patients
- سال انتشار: 1402
- محل انتشار: مجله فیزیک پزشکی ایران، دوره: 20، شماره: 3
- کد COI اختصاصی: JR_IJMP-20-3_004
- زبان مقاله: انگلیسی
- تعداد مشاهده: 198
نویسندگان
Physics Department, Faculty of Science, Zagazig University, Zagazig, Egypt.
Physics Department, Faculty of Science, Zagazig University, Zagazig, Egypt.
Clinical Oncology and Nuclear Medicine Department, Faculty of Medicine, El-Azhar University, Cairo, Egypt
Clinical Oncology and Nuclear Medicine Department, Faculty of Medicine, ZagazigUniversity, Zagazig, Egypt.
Radiation Oncology Department, International Medical Center (IMC), Egypt.
Clinical Oncology and Nuclear Medicine department, Zagazig University Hospitals, Egypt.
چکیده
Introduction: stereotactic body radiotherapy (SBRT) is the most proper treatment for multi lesions non-small cell lung cancer (NSCLC) for enhanced good coverage and minimizing dose to organs at risk (OARs). This study aims to compare single and dual isocenter SBRT plans and discuss which technique we can use in multi lesions NSCLC. Material and Methods: Ten patients with multi targets NSCLC underwent two different SBRT treatment planning techniques including single isocenter and dual isocenter. We quantitatively assessed plans qualities by dose-volume metrics. Conformity index (CI), Confirmation Number (CN), heterogeneity index (HI), gradient distance (GD), Gradient index (GI), and maximum percentage dose at ۲cm all around PTV ( ) were gathered, tallied, and statistically examined. OARs were evaluated and the dose to the normal lung was evaluated using V۵, V۱۰, V۲۰, and mean lung dose (MLD). Results: There is an insignificant difference between single and dual isocenter plans in CI, CN, HI, GD, GI, and dose spillage where the mean distance between two lesions was ۵.۵۰ ± ۱.۵۰ cm, and the mean total volume of the planning target volume (PTV) was ۴۲.۶۰±۲۱.۳۳cc. For single and dual isocenter plans, the median MLD was ۴.۵(۲-۱۶)Gy and ۴ (۲-۱۶)Gy respectively (p=۰.۲۵). Conclusion: Plan quality of single isocenter was equal to dual isocenter for SBRT treatment of multi lung lesions with maximum distances between them was ۱۰ cm. Dual isocenter took time during setup and matching for cone beam computed tomography (CBCT).کلیدواژه ها
Stereotactic Body Radiotherapy, VMAT, Lung cancerاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.