The Efficiency of Polyaluminum Silicate Chloride Coagulants in Nickel Removal from Aqueous Solutions

  • سال انتشار: 1401
  • محل انتشار: مجله آرشیو علوم بهداشتی، دوره: 11، شماره: 4
  • کد COI اختصاصی: JR_AHS-11-4_004
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 116
دانلود فایل این مقاله

نویسندگان

Mohammad javad Mohammadi

Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Department of Environmental Health Engineering, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

Afshin Takdastan

Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Department of Environmental Health Engineering, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

Mehdi Zhoolanezhad

Department of Environmental Health Engineering, Environmental Technologies Research Center, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

Abdolkazem Neisi

Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Department of Environmental Health Engineering, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

چکیده

Background & Aims: Nickel is one of the toxic heavy metals naturally released into the environment through industrial activities. Coagulation and flocculation are one of the available heavy metal removal methods, but experience has shown that high pH and the addition of coagulant aid are usually required to remove nickel by coagulation and flocculation process. This study aimed to examine the efficiency of polyaluminum silicate chloride (PASiC) coagulant in nickel removal from aqueous solutions. Materials and Methods: This study was conducted experimentally on a laboratory scale using the standard jar testing method. We investigated the effect of pH parameters (۴-۱۱), amount of coagulant (۷.۵-۷۵ mg/L based on aluminum), initial metal concentration (۱۰-۴۰۰ mg/L), and settling time (۱۵-۹۰ minutes). Nickel concentration was measured by flame atomic absorption spectroscopy. In this study, t test, between-groups ANOVA, and regression were used for analysis. Results: Results showed that the removal efficiency decreased at higher concentrations of nickel metal. Furthermore, increasing the settling time beyond ۳۰ minutes did not significantly change the removal efficiency. PASiC had a removal efficiency of over ۹۹% at an optimum pH of ۸, an optimum PASiC concentration of ۱۵ mg/L, an optimum time of ۳۰ minutes, and a nickel concentration of ۱۰-۱۰۰ mg/L. Conclusion: According to the results, the use of PASiC as a coagulant is a suitable option for removing nickel from polluted wastewater.

کلیدواژه ها

Water purification, Metals, Heavy, Coagulation, Flocculation, Nickel, Polyaluminum silicate chloride

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.