Comparing the Accuracy of Echocardiography and Radiography for Evaluation of Tip Position of Peripherally Inserted Central Catheters: Experienced in an NICU in Iran
- سال انتشار: 1402
- محل انتشار: مجله بین المللی کودکان، دوره: 11، شماره: 4
- کد COI اختصاصی: JR_INJPM-11-4_012
- زبان مقاله: انگلیسی
- تعداد مشاهده: 218
نویسندگان
Division of Neonatology, Department of Pediatrics Children’s Medical Center Tehran University of Medical Sciences
Pediatrics Department of Pediatrics, Division of pediatric cardiology, Children۰۳۹;s Medical Center, Tehran University of Medical Sciences, Tehran, Iran
۱. Associate professor, Neonatal Health Research Center, Research Institute for Children&#۰۳۹;s Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran ۲. Division of Neonatology, Department of Pediatrics, Children&a
Bc of Nursing, Children’s Medical Center, Tehran University of Medical Sciences, Tehran, Iran
Msc of Neonatal Intensive Care Nursing. Children’s Medical Center, Tehran University of Medical Sciences, Tehran, Iran
Msc of Neonatal Intensive Care Nursing. Children’s Medical Center, Tehran University of Medical Sciences, Tehran, Iran
Bc of Nursing, Children’s Medical Center, Tehran University of Medical Sciences, Tehran, Iran
Maternal & Child Health Specialist, Maternal, Fetal & Neonatal Research Center, Tehran University of Medical Sciences, Tehran, Iran
چکیده
Background: Echocardiography (ECHO) is a non-radiation real-time technique for evaluating Peripherally Inserted Central Catheter (PICC) tips that could overcome the limitations of plain radiographs, including the static and single image and exposing neonates to radiation. This study compared the accuracy of ECHO and radiography for PICC tip positioning in neonates. Methods: This cross-sectional pilot study was conducted in the neonatal intensive care unit (NICU) of the Children's Medical Center in Tehran, Iran. Ultrasonography was used to visualize the end of the catheter in the vessels. After insertion of the catheter, a chest x-ray along with the ECHO was performed by a pediatric cardiologist blinded to the preliminary radiographic reports, and the results were compared and interpreted.Results: Forty infants with mean gestational ages of ۳۵.۴±۳.۳ weeks were enrolled in this study which was conducted during ۱۲ months, from ۲۰۱۹ to ۲۰۲۰. The radiography results confirmed the correct PICC location in ۲۹ infants (۷۲.۵%), which was simultaneously confirmed by ECHO in ۲۸ infants (۷۰.۰%). The ECHO results indicated inappropriate placement in ۱۲ infants (۳۰%), and radiographs indicated correct placement in ۱۱ infants (۲۷.۵%). This confirmed the higher accuracy of ECHOکلیدواژه ها
Echocardiography,,, ,،neonate,,, ,،Peripherally inserted central catheter,,, ,،Radiographyاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.