A Data-Driven Design for Gas Turbines Exit Temperature Spread Condition Monitoring System
- سال انتشار: 1402
- محل انتشار: فصلنامه تحقیقات کاربردی در مهندسی صنایع، دوره: 10، شماره: 1
- کد COI اختصاصی: JR_APRIE-10-1_008
- زبان مقاله: انگلیسی
- تعداد مشاهده: 227
نویسندگان
Department of Industrial Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Department of Industrial Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Department of Industrial Engineering, Iran University of Science and Technology, Tehran, Iran.
چکیده
One of the most complex and costly systems in the industry is the Gas turbine (GT). Because of the complexity of these assets, various indicators have been used to monitor the health condition of different parts of the gas turbine. Turbine exit temperature (TET) spread is one of the significant indicators that help monitor and detect faults such as overall engine deterioration and burner fault. The goal of this article is to use data-driven approaches to monitor TET data to detect faults early, as fault detection can have a significant impact on gas turbine reliability and availability. In this study, the TET data of v۹۴.۲ GT is measured by six temperature transmitters to show a detailed profile. According to the statistical tests, TET data are high dimensional and time-dependent in the real world industry. Hence, three distinctive methods in the field of the gas turbine are proposed in this study for early fault detection. Conventional principal component analysis (PCA), moving window PCA (MWPCA), and incremental PCA (IPCA) were implemented on TET data. According to the results, the conventional PCA model is a non-adaptive method, and the false alarm rate is high due to the incompatibility of this approach and the process. The MWPCA based on V-step-ahead and IPCA approaches overcame the non-stationary problem and reduced the false alarm rate. In fact, these approaches can distinguish between the normal time-varying and slow ramp fault processes. The results showed that IPCA could detect fault situations faster than MWPCA based on V-step-ahead in this study.کلیدواژه ها
early fault detection, Data-Driven, Gas Turbine Exit Temperature, time-varying, PCA model, MWPCA model, IPCA modelاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.