Application of Molecularly Imprinted Polymer for SolidPhase Extraction and Preconcentration of Resorvastatin inbiological Sample Analysis

  • سال انتشار: 1401
  • محل انتشار: ششمین کنفرانس بین المللی مطالعات جهانی در علوم تکنولوژی و مهندسی
  • کد COI اختصاصی: ENGTCONF06_003
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 241
دانلود فایل این مقاله

نویسندگان

Azam Ghorbani

Department of Chemistry, Collage of Technology and Engineering Saveh BranchIslamic Azad University, Saveh, Iran

چکیده

A molecularly imprinted polymer (MIP) was synthesized and evaluated to selectivelyextraction of Resorvastatin, a HMG-COA reductase inhibitors in human urine samples. Thesynthesis of the MIP was performed in methacrylic acid (MAA) as the functional monomer,ethylene glycol dimethacrylate (EGDMA) as the cross-linker monomer, chloroform as thesolvent and Resorvastatin, template as the target drug. Ultraviolet spectroscopy, FT-IRspectroscopy, UV-VIS spectrophotometry, thermogravimetric analysis were performed tointerpret the specific recognition ability, the binding process and the characteristics of MIPs.In this study, solid phase extraction using the imprinted polymer has been optimized with theexperimental design approach for Resorvastatin, with regard to the critical factors whichinfluence the molecular imprinted solid phase extraction efficiency such as sample pH,volume of elution solvent, washing solvent and sorbent mass. Batch rebinding capacity ofResorvastatin was determined from the derived Freundlich isotherm and was found to be۱.۴۵μmolg-۱. The recovery and limit of detection for urine sample were ۹۸% and ۵.۹ μgL−۱,respectively. The results showed that, compared with other reports, MIPs synthetized in thisstudy showed high adsorption capacity besides specific recognition ability. The synthesizedMIP has enabled the direct percolation of human urine and the easy elimination of endogenouscompounds from it with simple aqueous washing of the MIP-SPE packing. HPLC analysishas confirmed the high extraction recovery of resorvastatin, from such urine samples with useof proposed MIP-SPE system.

کلیدواژه ها

Molecularly imprinted polymer , biological sample, Resorvastatin, High performance liquidchromatography.

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.