Application of Multivoxel ۱H-Magnetic Resonance Spectroscopy in the Grading of Cerebral Glioma

  • سال انتشار: 1402
  • محل انتشار: مجله فیزیک پزشکی ایران، دوره: 20، شماره: 2
  • کد COI اختصاصی: JR_IJMP-20-2_006
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 231
دانلود فایل این مقاله

نویسندگان

Erfan Saatchian

medical physics, medical faculty mashhad university of medical science mashhad iran

sina Ehsani

Department of medical physics, Medicine Faculty, Mashhad University of Medical sciences, Mashhad, Iran

Farnoosh Musavi

Department of medical imaging, Medicine Faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran

چکیده

Introduction: Gliomas represent a considerable percentage of all diagnosed primary central nervous system tumors. A non-invasive access method, like magnetic resonance spectroscopy (MRS), is required for preoperative evaluation. So, the present study aimed to evaluate the application of Multivoxel ۱H-MR Spectroscopy in the differentiation of high-grade from low-grade gliomas.Material and Methods: ۱۳ patients suspected of Cerebral Glioma, which already had been selected for brain surgery or biopsy, underwent a Multivoxel ۱H-MR Spectroscopy. After the MRS exam, the pathology tests on specimens confirmed the grade of tumors. Then results were compared and represented as receiver operating characteristic (ROC) curves to show their sensitivity and specificity as well.Results: Choline to creatine (Cho/Cr) and choline to N-acetyl-aspartate (Cho/NAA) were statistically lower in the low-grade group than in high-grade (p=۰.۰۰۷ and p=۰.۰۲۷, respectively) and N-acetyl-aspartate to creatine (NAA/Cr) was statistically higher in the high-grade group (p=۰.۰۳۷). But in border regions, only Cho/Cr and Cho/NAA were significant (P values= ۰.۱۹ and ۰.۲۲, respectively). With receiver operating characteristic (ROC) curves analysis, Cho/Cr had the best sensitivity and specificity in the differentiation of high-grade from low-grade gliomas in tumor area (۹۲.۸۶% sensitivity and ۸۵.۷۱% specificity) and this ratio had the best sensitivity and specificity in border regions of tumor (۹۲.۸۶% sensitivity and ۷۸.۴۳% specificity).Conclusion: Metabolite ratios of low and high-grade gliomas (HGG) were significantly different from each other. Cho/Cr and Cho/NAA ratios can use as an internal reference for grading the glioma non-invasively in the tumor area and the border area of the tumor.

کلیدواژه ها

Magnetic Resonance Spectroscopy, Neoplasms, Neoplasm Grading

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.