The Capability of Silver Nanoparticles Modified ۴-Amino-۳-hydrazino-۵-mercapto-۱,۲,۴-triazole for Early Detection of Cortisol as a Stroke Biomarker

  • سال انتشار: 1402
  • محل انتشار: مجله تحقیقات شیمی تجزیه و تجزیه زیستی، دوره: 10، شماره: 3
  • کد COI اختصاصی: JR_ANALCH-10-3_007
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 79
دانلود فایل این مقاله

نویسندگان

Hanim Badi’ah

Departement of Chemistry, Faculty of Science and Technology, Airlangga University, Kampus C Mulyorejo, Surabaya ۶۰۱۱۵, Indonesia. Departement of Medical Laboratory Technology, Institute of Health Science Banyuwangi, Jl. Letkol Istiqlah No. ۱۰۹

Ni Nyoman Puspaningsih

Departement of Chemistry, Faculty of Science and Technology, Airlangga University, Kampus C Mulyorejo, Surabaya ۶۰۱۱۵, Indonesia

Ganden Supriyanto

Departement of Chemistry, Faculty of Science and Technology, Airlangga University, Kampus C Mulyorejo, Surabaya ۶۰۱۱۵, Indonesia

Nasronudin Nasronudin

Faculty of Medicine, Airlangga University, Kampus C Mulyorejo, Surabaya ۶۰۱۱۵, Indonesia

چکیده

Silver nanoparticles modified with ۴-amino-۳-hydrazino-۵-mercapto-۱,۲,۴-triazole (AgNPs-AHMT) have been developed as colorimetric sensors for cortisol detection as a stroke biomarker. This method’s principle was based on AgNPs-AHMT aggregation with cortisol due to the hydrogen bonding interaction between the surfaces of AHMT and cortisol. This process caused the color change that can be seen with the naked eye. Then, it is confirmed by ultraviolet-visible (UV-Vis) spectroscopy, particle size analyzer (PSA), Fourier transform infrared (FTIR) spectroscopy, and transmission electron microscopy (TEM). The color of colloidal AgNPs-AHMT changed from yellow to brownish orange, giving a red shift in the localized surface plasmon resonance (LSPR) peak. The quantitative monitor for cortisol determination had good linearity in the range of cortisol concentrations of ۱.۰–۵۰.۰ nM, with a limit of detection (LOD) and a limit of quantification (LOQ) of ۰.۷۱۹ nM and ۲.۳۷ nM, respectively. The relative standard deviations (RSD %) for intra-day and inter-day were < ۳.۲ % and < ۲.۲۶ %, respectively. Moreover, this method was applied for cortisol detection in a saliva sample. So, the simple, rapid, and real-time strategy exhibited a promising potential for cortisol detection in a saliva sample.

کلیدواژه ها

Silver nanoparticles, ۴-Amino-۳-hydrazino-۵-mercapto-۱, ۲, ۴-triazole, cortisol, Colorimetric sensing

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.