Marginal adaptation of zirconia CAD-CAM copings with two cervical finish lines

  • سال انتشار: 1402
  • محل انتشار: مجله مواد و تکنیک های دندانپزشکی، دوره: 12، شماره: 1
  • کد COI اختصاصی: JR_JDMT-12-1_003
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 234
دانلود فایل این مقاله

نویسندگان

Maryam Moslemioon

Department of Prosthodontics, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran.

Faeze Zanjani Jam

Undergraduate Student, Zanjan University of Medical Sciences, Zanjan, Iran

Rasoul Moharami

Mechanical Department, University of Zanjan, Zanjan, Iran.

Atefeh Yousefi Jordehi

Department of Operative Dentistry, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran

چکیده

Introduction: Marginal adaptation is important for the long-term success of restorations. The finish line design can influence the marginal integrity. This study aimed to evaluate the effect of radial shoulder and deep chamfer finish line designs on the marginal adaptation of zirconia copings fabricated by the CAD-CAM system. Methods: In this experimental study, a standard chrome-cobalt die (height: ۷mm, diameter: ۵mm) was designed by software. The data were sent to a ۳D printer device, and the resin pattern of the standard die was fabricated. After casting the resin pattern, a standard chrome-cobalt die was obtained with a ۱-mm radial shoulder finish line and a ۰.۸-mm deep chamfer finish line. The walls were ۱۲° converge (۶° each) towards the occlusal surface. The standard die was replicated ۹ times with a polyvinyl siloxane elastomeric material and poured with type IV dental stone. Zirconia copings were fabricated, and the vertical gap at ۸ points was measured by a stereo microscope. Data were analyzed by the t-test, and statistical significance was set at α=۰.۰۵.Results: The vertical gap values were ۱۰۲.۹۱ µm for deep chamfer and ۸۲.۴۲ µm for radial shoulder finish lines. There was no significant difference between the two preparation designs in terms of the mean vertical gap (P=۰.۰۹۸).Conclusion: The results of this study showed clinically acceptable marginal adaptation values for both deep chamfer and radial shoulder preparation designs without a statistically significant difference.  (J Dent Mater Tech ۲۰۲۳;۱۲(۱): ۱۶-۲۱)

کلیدواژه ها

CAD-CAM, marginal adaptation, Zirconia

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.