Multi-walled Carbon Nanotubes/Ionic Liquid Nanocomposite Modified Carbon-ceramic Electrode: Electrochemistry and Measurement of Tryptophan in the Presence of Uric Acid

  • سال انتشار: 1396
  • محل انتشار: مجله تحقیقات شیمی تجزیه و تجزیه زیستی، دوره: 4، شماره: 1
  • کد COI اختصاصی: JR_ANALCH-4-1_013
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 196
دانلود فایل این مقاله

نویسندگان

Biuck Habibi

Electroanalytical Chemistry Laboratory, Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz ۵۳۷۱۴-۱۶۱, Iran

Zahra Ayazi

Electroanalytical Chemistry Laboratory, Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz ۵۳۷۱۴-۱۶۱, Iran

Maryam Dadkhah

Electroanalytical Chemistry Laboratory, Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz ۵۳۷۱۴-۱۶۱, Iran

چکیده

In the present work, an efficient modified carbon-ceramic electrode by multi-walled carbon nanotubes/ionic liquid nanocomposite (MWCNTs/IL/CCE) was prepared through a simple and repeatable procedure. The introduced modified electrode was used for the study of the electrochemical behaviour and determination of tryptophan (Trp) in the presence of uric acid (UA) using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and amperometry techniques. The MWCNTs/IL/CCE exhibited high electrocatalytic activity toward the oxidation of Trp in phosphate buffer solution (pH ۷.۰) which led to produce an anodic peak at about ۰.۶۷ V vs. saturated calomel electrode. The influential parameters such as pH, amount and ratio of MWCNTs/IL in the nanocomposite modifier on the electrocatalytic activity of the MWCNTs/IL/CCE were studied and optimized. Under the optimum conditions, the anodic peak current in DPV method is linear for the Trp concentrations in the ranges of ۵×۱۰-۷ M to ۷×۱۰-۵ M with a correlation coefficient of ۰.۹۹۸ and detection limit of ۳.۲×۱۰-۷ M (S/N=۳). The relative standard deviation of the anodic peak current obtained for a ۵.۰×۱۰-۵ M Trp solution was ۲.۲% (n=۶). Finally, DPV method was applied for simultaneous determination of Trp and UA, which demonstrates the applicability of the present modified electrode.

کلیدواژه ها

Multi-walled carbon nanotubes, Ionic Liquid, Nanocomposite, tryptophan, Uric Acid, Simultaneous determination, Modified electrode

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.