Quality of Radiosurgical Plans by Leksell Gamma Knife Perfexion in the Treatment of Meningioma: Comparison between two isodose lines (۵۰% and ۷۵%)

  • سال انتشار: 1402
  • محل انتشار: مجله فیزیک پزشکی ایران، دوره: 20، شماره: 1
  • کد COI اختصاصی: JR_IJMP-20-1_004
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 311
دانلود فایل این مقاله

نویسندگان

Gad Elbaz

Gamma knife unit ,Neurosurgery department,faculty of Medicine AL-Azhar university,Damietta,Egypt.

Hedaya Hendam

Gamma knife Damietta Center, Department of Neurosurgery, faculty of medicine, Damietta Azhar university Hospital. Cairo, Egypt.

Elsayed Alashkar

Biophysics Branch, Physics Department, Faculty of Science, Cairo Azhar University. Cairo, Egypt.

Hussein ABOUELGHEIT

M.D of Neurosurgery ,Stereotaxy and Functional Neurosurgery Unit, Neurological Surgery Department, Tanta University, Egypt. Marseille, Aix Marseille, ۲۶۴ Rue Saint Pierre, Marseille-۱۳۰۰۶, Marseille-France

Khairy Ereiba

Biophysics Branch, Physics Department, Faculty of Science, Cairo Azhar University. Cairo, Egypt

Ehab Attalla

Department of Radiotherapy and Nuclear Medicine, National Cancer Institute, Cairo;University, Cairo, Egypt

چکیده

Introduction: Radiosurgery is a well-established available technique for treating many diseases and indications. Planning quality assessment is a crucial step in the procedure itself and outcome probabilities; either control or complication probability. Several physical indices and methodology have been developed to describe any plan. Accordingly, plan quality and outcome could be compared with other plans. In current study, the aim was to compare two plans with different isodose line using radiobiological model, tumor control probability (TCP), normal tissue complication probability (NTCP) and plan’s physical indices.   Material and Methods: The cross-sectional study included ۲۰ patients (۵ male and ۱۵ female) with median age of ۴۴ years (۲۱-۶۶) and presented with radiologically diagnosed meningioma. Two radiosurgical forward plans were applied with same marginal dose of ۱۲Gy at two different isodose lines of ۵۰% and ۷۵% isodose alternatively using Leksell Gamma Plan of single session GKS. Dose-Volume Histogram (DVH) was imported to MATLAB to compute TCP, NTCP values at ۵ years for each plan, and physical indices such as coverage, selectivity, conformity, heterogeneity, and gradient indices.Results: Median target irradiated volume was ۷.۵ cm۳ (۰.۵۸۸ -۲۳.۷۲). TCP was significantly higher in the plan using ۵۰% isodose line for the marginal dose than that using ۷۵% isodose line (۹۵.۰۵%, ۴۹.۴۴%, p< ۰.۰۵, Independent Samples t-Test). Brainstem and optic apparatus NTCPs were very low ۰.۰۱% (۰-۰.۰۴۵%) in the former plan and zero in the later one (p =۰.۰۰۱, Mann-Whitney test).Conclusion: Radiobiological models and physical indices could be used for the optimum plan selection of GKS

کلیدواژه ها

Gamma Knife radiosurgery, Tumor control probability, Normal tissue complication probability, Dose Volume Histogram, Treatment Planning Parameters

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.