Acetabular Screw in Close Proximity to the Posterior Branch of the Internal Iliac Artery in Revision Hip Surgery with Intrapelvic Migration of Acetabular Component: Preoperative Placement of a Fogarty Catheter in the Internal Iliac Artery (Case Report

  • سال انتشار: 1402
  • محل انتشار: مجله استخوان و جراحی عمومی، دوره: 11، شماره: 1
  • کد COI اختصاصی: JR_TABO-11-1_008
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 109
دانلود فایل این مقاله

نویسندگان

Deepak Gautam

Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India

Atin Kumar

Department of Radiodiagnosis, All India Institute of Medical Sciences, New Delhi, India

Arun Manjunatha Swamy

Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India

Vivek Vijayakumar

Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India

Alok Rai

Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India

Rajesh Malhotra

Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India

چکیده

Revision of an intrapelvic migration of the acetabular component of a total hip is a challenging surgery due to the risk of injury to the pelvic viscera. The primary concern is vascular injury due to the risk of mortality and limb loss. The researchers present one case where the acetabular screw was near the posterior branch of the internal iliac artery. A Fogarty catheter was placed in the internal iliac artery preoperatively, and the amount of fluid to inflate the catheter and completely block the artery was determined. The catheter was kept in a deflated condition. The hip reconstruction was performed, and there was no incidence of vascular injury during the procedure; hence, the Fogarty catheter was removed postsurgery. The placement of a Fogarty catheter in the at-risk vessel provides the freedom to proceed with the hip reconstruction through the standard approach. In case of an inadvertent event of a vascular injury, it can be inflated with the predetermined amount of saline to check the bleeding until the vascular surgeons take over the case. Level of evidence: V

کلیدواژه ها

Complex hip revision, Intra-pelvic migration, Fogarty, Vascular injury

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.