Parameter Identification of 7th Order Model of Synchronous Generator by EKF

  • سال انتشار: 1391
  • محل انتشار: بیستمین کنفرانس مهندسی برق ایران
  • کد COI اختصاصی: ICEE20_270
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 1618
دانلود فایل این مقاله

نویسندگان

E. Fallah

Engineering Faculty, University of Guilan,

M.M Asiaban

Engineering Faculty, University of Guilan

چکیده

Synchronous generators play a very important role in the stability of power systems. A valid model for synchronous generators is essential for a reliable analysis ofstability and dynamic performance. Accurate generator modelling allows for more precise calculations of power system control and stability limits. System identification instate space form, particularly when physical parameters of a system are required, has certain advantages. In this paper,nonlinear parameter estimation of synchronous generators using Extended Kalman Filter is addressed. The proposed method is applied to identify Seventh order model of asynchronous generator parameters. In this study, the rotor speed, the instantaneous values of the stator current and theterminal voltage and the instantaneous value of the excitation current are considered as the measurable outputs of the synchronous generator.

کلیدواژه ها

Synchronous Generator;Parameter Estimation; Extended Kalman Filter;7th Order Model

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.