CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

A Proposed Methodology for Magnetic Resonance Images' Geometrical Distortion Correction Intended To Use For Radiotherapy Planning Using a Large Inhouse Field of View

عنوان مقاله: A Proposed Methodology for Magnetic Resonance Images' Geometrical Distortion Correction Intended To Use For Radiotherapy Planning Using a Large Inhouse Field of View
شناسه ملی مقاله: JR_IJMP-19-5_007
منتشر شده در در سال 1401
مشخصات نویسندگان مقاله:

Shahrokh Naseri - Department of medical physics, Faulty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran
Mehdi Momennezhad - Mashhad University Of Medical sciences
Atefeh Rostami - Department of Medical Physics and Radiological Sciences, Sabzevar University of Medical Sciences, Sabzevar, Iran
Hoda Zare - Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
Kazem Anvari - Department of Radiotherapy Oncology and Cancer Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
Hamed Reza Sayah - Kowsar MRI Center, Emam Reza Hospital, Mashhad, Iran
Vajiheh Vejdani Noghreiyan - Medical Physics and Radiological Sciences Department, Sabzevar University of Medical Sciences

خلاصه مقاله:
Introduction: Exquisite soft tissue contrast of magnetic resonance images (MRI) and the new combined radiotherapy system of MR-Linac have been the main impetus for applying MR imaging in radiotherapy. One limitation of MR-based radiotherapy is the geometric distortion of MR images that can generate errors in the contouring and dosimetry stages. This study aimed to evaluate and correct geometric distortion for radiotherapy applications. Material and Methods: A large field of view (FOV) phantom develop using Perspex sheets and ۳۲۵ plastic pipes. The quantification and correction of MR images' system-related geometric distortion are conducted for HASTE protocol by MATLAB and ۳D slicer software in phantom and patient images. The effect of MRI images geometrical distortion was evaluated for ten patients undergoing body radiotherapy treatment.  CT images were used as a primary dataset to estimate the distortion map. Results: The phantom investigation results indicate that in radial distances of < ۱۳ cm (or FOVs < ۲۵ cm), the amount of distortion is under ۲ mm. Still, at more considerable radial distances, distortion may increase up to about ۳.۵ cm. MR images of Patients with lateral (LAT) and anterior-posterior (AP) diameters of more than ۳۸ cm and ۲۵ cm respectively, need to be corrected for geometric distortion.   Conclusion: MR images' geometric precision in large FOVs is not sufficient for MRI only treatment planning of radiotherapy and further corrections are required. The B-spline deformable registration method can correct the MR geometric distortion until an acceptable range of ۲ mm for radiotherapy applications.

کلمات کلیدی:
Geometrical Distortion Spatial Distortion Correction ۳D Slicer Scatter Transform B, Spline Deformable Registration

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1522392/