Effects of Adding TiO۲ Nanoparticles on Flexural Strength and Hardness of Two New Commercial Flowable Dental Composites

  • سال انتشار: 1401
  • محل انتشار: مجله مواد و تکنیک های دندانپزشکی، دوره: 11، شماره: 2
  • کد COI اختصاصی: JR_JDMT-11-2_001
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 182
دانلود فایل این مقاله

نویسندگان

Fatemeh Koohpeima

Department of Operative Dentistry, Biomaterial Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

Mohammad Javad Mokhtari

Department of Biology, Zarghan Branch, Islamic Azad University, Zarghan, Iran

Sajjad Khaksabz

Department of Operative Dentistry, Biomaterial Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

چکیده

Introduction The present study aimed to investigate the effect of adding TiO۲ nanoparticles on the flexural strength and hardness of two dental composites. Methods: TiO۲ nanoparticles were prepared and added to two flowable dental composites (Beautifil Flow Plus and Clearfil AP-X Flow) at ۰, ۰.۲, ۰.۵, and ۱% (w/w) which was confirmed by SEM and TEM analysis. Mixing was manually performed using Lentulo Spiral Paste Carrier. The specimens were divided into ۸ groups of ۱۰ according to the type of composites and different concentrations of TiO۲ nanoparticles. Bar-shaped specimens (۲×۲×۲۵ mm) were fabricated in a half-split stainless steel mold and cured for ۴۰ s by an LED curing system. Flexural strength was evaluated using a universal testing machine. Surface microhardness was also measured by the Vickers microhardness tester. Results: For the two tested composites, flexural strength increased by ۰.۵% TiO۲ nanoparticles concentration. The flexural strength of Clearfil AP-X Flow combined with ۰.۲, ۰.۵ and ۱% TiO۲ nanoparticles were ۱۱۲.۵۴±۱۲.۸۷ (P> ۰.۰۵), ۱۱۴.۶۲±۸.۱۴ (P> ۰.۰۵), and ۹۹.۹۲±۶.۲۳ (P< ۰.۰۵), respectively. Also, for Beautifil Flow combined with ۰.۲, ۰.۵ and ۱% TiO۲ nanoparticles were, ۹۲.۲۱±۴.۲۶ (P< ۰.۰۵), ۹۴.۰۵±۵.۳۶ (P< ۰.۰۵) and ۷۴.۱۷±۹.۴۳ (P< ۰.۰۵), respectively. Conclusion: Adding TiO۲ nanoparticles to Clearfil AP-X Flow composite decreased the hardness; however, adding TiO۲ nanoparticles by ۱% concentration increased the surface hardness of Beautifil Flow and reached its maximum value. Also, TiO۲ nanoparticles at very low concentrations enhance the flexural strength of dental flowable composites.

کلیدواژه ها

flowable composite, Nanoparticles, surface hardness, Titanium dioxide

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.