Investigating The Effect Of Different Inclinations Of Maxillary Occlusal Plane On Estimating The Size Of Gutta-Percha Markers In Cbct Images: An In-Vitro Study

  • سال انتشار: 1400
  • محل انتشار: فصلنامه بین المللی تحقیقات پزشکی، دوره: 10، شماره: 4
  • کد COI اختصاصی: JR_INTJMI-10-4_017
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 204
دانلود فایل این مقاله

نویسندگان

Hoda Abbaspour Tehrani Fard

Private Dentist, Tehran Iran.

Ladan Hafezi

Assistant professor, Oral and Maxillofacial Radiology Department., Dental School, Islamic Azad University of Medical Sciences, Tehran, Iran.

Amirreza Mehdizadeh

Post-graduate Student, Oral and Maxillofacial Radiology Department, Dental School, Islamic Azad University of Medical Sciences, Tehran, Iran

Niloofar Ghadimi

Post-graduate Student, Oral and Maxillofacial Radiology Department, Dental School, Islamic Azad University of Medical Sciences, Tehran, Iran

Afsoon Jalali Ara

Post-graduate Student, Oral and Maxillofacial Radiology Department, Dental School, Islamic Azad University of Medical Sciences, Tehran, Iran

Ahmadreza Talaipour

Professor, Oral, and Maxillofacial Radiology Department, Dental School, Islamic Azad University of Medical Sciences, Tehran, Iran.

چکیده

Background: Due to the importance of CBCT linear measurement accuracy and the lack of standard axial plane inclination, this study aimed to investigate the effect of axial plane inclination changes on linear measurement accuracy in reconstructed maxillary CBCT images. Materials and Methods: In the present experimental (in-vitro) study, CBCT images were obtained from ۳ dry human maxillae. In this study, radiopaque markers (gutta-percha) were used as landmarks. First, real measurements were made by a practitioner using a digital caliper. Then, CBCT was taken in ۵ different inclinations of the axial plane (parallel to the occlusal plane as the standard plane and ±۷ ̊and ±۱۴ ̊). One observer performed radiographic linear measurements. The linear measurements were a total of ۵۴۰ samples according to ۳۶ markers and ۵ different inclinations and ۳ replications. Physical and radiographic linear measurements were compared to evaluate the accuracy of linear measurements on ۵ different inclinations. Data were analyzed using SPSS software version ۱۶ and ANOVA test. Results: A total of ۵۴۰ samples with ۵ different inclinations were evaluated. The actual size of the marker length, inclinations estimation and difference estimation showed that the maximum and minimum differences were related to inclinations of -۷ ̊ by ۰.۰۰۹ and inclinations of +۷ ̊ by ۰.۰۰۲, respectively. However, ANOVA test showed that this estimate of differences in various inclinations was not statistically significant (P > ۰.۰۵). Conclusion: It seems that changing the inclination from ۰ to -۱۴ does not affect estimating the real differences of marker length with the inclination. Therefore, it can be concluded that all vertical measurements are accurate clinically.

کلیدواژه ها

Cone beam computed tomography, Linear measurements, Maxilla

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.