Detection of Cd (II) in Tape Water Sample Using Glassy Carbon Electrode Modified by Nano-Sized Ion Imprinted Polymer and Physically Modified Graphene Composite

  • سال انتشار: 1400
  • محل انتشار: چهارمین کنفرانس بین المللی توسعه فناوری در مهندسی شیمی
  • کد COI اختصاصی: CHEMISB04_039
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 431
دانلود فایل این مقاله

نویسندگان

Vali Alizadeh

Department of Petroleum Engineering, Faculty of Engineering, University of Garmsar, Pobox:۳۵۸۱۷۵۵۷۹۶,Garmsar, Iran

Nasrin Behnia

Islamic Azad University Central Tehran Branch, Tehran, Iran

Mehdi Asgari

Technical Department, ARA G. T. Company, Dubai, United Arab Emirates

چکیده

A selective and sensitive electrochemical sensor was prepared by film coating of Cd (II) ion imprinted polymer (IIP) nanoparticle and Pyrenecarboxylic acid (Py)modified graphene (Gr) composite on glassy carbon electrode (GCE). The prepared electrochemical sensor was applied for the sensitive determination of Cd (II) ion by square wave anodic stripping voltammetry (SWASV) method. The GCE/IIP-Py-Gr modified electrode showed improved electrochemical behavior as compared to bare GC electrode. An optimum procedure was used for the fixation of Zn(II)-۸-hydroxyquinoline to styrene-ethylene dimethacrylate copolymer and the resultant IIP nanoparticles characterized by Fourier Transform Infrared ( FTIR), thermal gravimetric analysis (TGA), and scanning electron microscopy (SEM). The effects of different experimental variables such as pH, deposition time, and deposition potential were optimized for electrochemical determinations. The resultant IIP showed a selective sorbent for Cd (II) ion. Py -Gr was applied in construction of as prepared modified electrode, exhibits large surface area, enhanced electron transfer kinetics, and improved Cd (II) ion diffusion. Under the optimal conditions, the resulting calibrationcurve exhibited a linear response within a concentration range of ۵×۱۰-۱۲ to ۱۵×۱۰-۸ mol/L-۱ with excellentdetection limit ۵×۱۰-۱۲mol/L-۱. Finally, the method was successfully applied for the determination of Cd (II) ion in the tape water sample successfully, and the obtained results were verified by inductively coupled plasma (ICP).

کلیدواژه ها

Imprinted Polymer, Graphene, Square wave Anodic Stripping Voltammetry, Glassy carbon electrode.

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.