Investigation of bacterial contamination of medical surfaces and equipment in the neonatal and NICU wards of Shahid Beheshti Hospital In Isfahan

  • سال انتشار: 1400
  • محل انتشار: بیست دومین کنگره میکروب شناسی ایران (مجازی)
  • کد COI اختصاصی: MEDISM22_126
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 275
دانلود فایل این مقاله

نویسندگان

Tayebe Shakiba dastgerdi

Department of Microbiology, School of Medicine,Isfahan University of Medical Science,Isfahan,Iran

Vajihe Karbasizade

Department of Microbiology, School of Medicine,Isfahan University of Medical Science,Isfahan,Iran

Alireza Sadeghnia

Department of Paediatrics,School of Medicin ,Imam Hossein Hospital ,Isfahan University of Medical Science ,Isfahan ,Iran

چکیده

Background and Aim : Nosocomial infection is an important cause of mortality in neonatal and NICU wards.continuous monitoring and care for microbial contamination of these wards is one of the effective strategies to prevent nosocomial infections.The aim of this study was to determine the bacterial contamination of equipment in the neonatal and NICU wards of shahid Beheshti Hospital in IsfahanMethods : In a descriptive study of ۶۳ devices in the neonatal and NICU departmens sampling was performed before and after routin disinfction ,samples were taken with a sterile swab impregnated with TSB medium and placed inside a tube containing TSB.Identification of isolates was performed first by conventional biochemical tests and then by ۱۶SrRNA gene amplification and molecular sequencing Results : Of the ۶۳ items before disinfection, ۳۸ (۶۰.۳% )were positive for bacterial contamination . of the ۶۳ items after disinfection, ۱۲ (۱۹.۰۴% )were positive for bacterial contamination.The most abundant bacterial isolate before and after disinfection Negative coagulase Staphylococcus respectively inabundance (۵۷.۱۴% )and (۱۹.۰۴% ) was .The highest contamination of non-medical devices before and after disinfection related to the patients cartable is ۱۰۰ and ۵۰ respectively and the highest contamination of medical devices before and afte disinfection related to the Lrayngoscope blade is ۱۰۰ and ۵۰ respectivelyConclusion : This study showed that bacterial contaminatin is significant .Periodic culture and use of standard guidelines and prevention have an effective rolein reducing contamination

کلیدواژه ها

Bacterial contamination ,NICU, Negative coagulase Staphylococcus,Neonation

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.