Exergy analysis of Shazand power plant’s boiler

  • سال انتشار: 1390
  • محل انتشار: هشتمین همایش ملی انرژی
  • کد COI اختصاصی: NEC08_141
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 2103
دانلود فایل این مقاله

نویسندگان

Hadi Jafari

Department of Mechanical Engineering, K.N. Toosi University of Technology

Amin Engarnevis

Department of Mechanical Engineering, K.N. Toosi University of Technology

Ali Behbahaninia

Department of Mechanical Engineering, K.N. Toosi University of Technology

چکیده

In this study, The exergy analysis of Shazand power plant’s boiler is presented. The aim of this study is to use energy and exergy analysis to identify the locations and magnitudes of losses in order to maximize the performance of a boiler.The results indicate that about 48 % of heat energy generated in the boiler is destroyed. Also results, show that the major irreversibilities are due to losses Furnace system. That ensue, combustion process is The most effective factor in irreversibilty of boiler.

کلیدواژه ها

Exergy Analysis, Energy, Steam Power Plant, Boiler efficiency