Comparison between 2D-FEM and 3D-FEM Dynamic Performances of Switched Reluctance Motor

  • سال انتشار: 1390
  • محل انتشار: چهاردهمین کنفرانس دانشجویی مهندسی برق کشور
  • کد COI اختصاصی: ISCEE14_397
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 1923
دانلود فایل این مقاله

نویسندگان

S Darabi

Department of Elec. Eng. K.N.Toosi University of Technology

چکیده

Although many researchers use two-dimensional finite-element (2D-FEM) to analyze rotary motors, this paper presents that 2D-FEM is not always reliable. In this paper, the dynamic analysis of an 8/6 SRM based on FEM is performed. The SRM has been analyzed with Ansoft Maxwell. The results are shown that 2D-FEM is not acceptable compared to 3DFEM. The relative error in Mean value of moving torque ( ) is 17.17 %. 17% error in mean value of moving torque shows 2D-FEM’s weakness to analyze SRM. Although 2D-FEM has simple principles, the design of the motor using FEM requires a careful consideration of all flux paths. The advantage of 3DFEM compared to 2D-FEM is consideration of all flux paths.

کلیدواژه ها

Switched reluctance motor (SRM), 2D-FEM,3D-FEM