The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.

  • سال انتشار: 1399
  • محل انتشار: مجله مکانیک کاربردی محاسباتی، دوره: 51، شماره: 2
  • کد COI اختصاصی: JR_JCAM-51-2_014
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 268
دانلود فایل این مقاله

نویسندگان

Ana Rita Carreiras

Engenharia Mecânica, ISEP, Instituto Superior de Engenharia do Porto, Porto, Portugal

Elza M. M. Fonseca

LAETA, INEGI, Engenharia Mecânica, ISEP, Instituto Superior de Engenharia do Porto, Porto, Portugal

Diana Martins

Engenharia Mecânica, ISEP, Instituto Superior de Engenharia do Porto, Porto, Portugal

Rui Couto

Engenharia Mecânica, ISEP, Instituto Superior de Engenharia do Porto, Porto, Portugal

چکیده

This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. For this purpose, ۲D axisymmetric computational models of an implant-cement-bone (Model ۱), implant-bone (Model ۲) and core implant-bone (Model ۳) were constructed using the finite element method with ANSYS program. The finite element model was assumed a state of ideal osseointegration, where the cortical bone, cement and implant were assumed as perfectly bonded. Three different implant diameters were chosen and two materials considered, a typical titanium alloy and iso-elastic titanium alloy with low stiffness. The finite element analysis was carried out to calculate the von Mises stress, the shear stress and the strain energy density in all studied models. Also, an analytical procedure, based on the elastic stress theory and applied to composite materials for an axial load, was used to measure the load transferred to the bone. In all results, Model ۳ with the vertical graded iso-elastic alloy in vicinity to the bone with high diameter has a good performance.

کلیدواژه ها

Stiffness, Bone, Numerical model, Load transferred to the bone

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.