Gas Pipeline Corrosion Mapping Using Pulsed Eddy Current Technique

  • سال انتشار: 1390
  • محل انتشار: مجله بین المللی طراحی پیشرفته و تکنولوژی ساخت، دوره: 5، شماره: 1
  • کد COI اختصاصی: JR_ADMTL-5-1_002
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 181
دانلود فایل این مقاله

نویسندگان

M. S. Safizadeh

M. Hasanian

چکیده

Oil and gas transmission pipelines are critical items of infrastructure in providing energy sources to regions and countries. Steel pipes are commonly used which can be subject to both internal and external corrosion. This paper presents an advanced nondestructive inspection technique for detection of oil-gas pipeline corrosion defect. The Pulsed Eddy Current (PEC) method has been successfully applied in corrosion detection of unburied gas pipeline without removing the insulation. First, the principles of pulse eddy current method is pointed out then, the pulsed eddy current test on a pipe is simulated by Maxwell software to obtain optimum test parameters. To test the new technique, some artificial defects are fabricated on the inner surface of a gas pipe to simulate different corrosions phenomena in practice. Three isolation layers are applied to the pipe in order to show the efficiency of PEC in the detection of wall thinning areas without removing the insulation.

کلیدواژه ها

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.