Hearing Assessment of Neonates Treated in the Neonatal Intensive Care Unit of Besat Hospital in ۲۰۱۸-۲۰۱۹
- سال انتشار: 1398
- محل انتشار: مجله علمی پژوهشی دانشگاه علوم پزشکی زنجان، دوره: 28، شماره: 127
- کد COI اختصاصی: JR_ZUMS-28-127_002
- زبان مقاله: انگلیسی
- تعداد مشاهده: 260
نویسندگان
Hearing Disorders Research Center, Besat Hospital, Hamadan University of Medical Sciences, Hamadan, Iran
Hearing Disorders Research Center, Besat Hospital, Hamadan University of Medical Sciences, Hamadan, Iran
Hearing Disorders Research Center, Besat Hospital, Hamadan University of Medical Sciences, Hamadan, Iran
Hearing Disorders Research Center, Besat Hospital, Hamadan University of Medical Sciences, Hamadan, Iran
Hearing Disorders Research Center, Besat Hospital, Hamadan University of Medical Sciences, Hamadan, Iran
Hearing Disorders Research Center, Besat Hospital, Hamadan University of Medical Sciences, Hamadan, Iran
چکیده
Background and Objective: Early detection of neonatal hearing disorders is a suitable measure of speech and behavioral development. The aim of this study was to determine the prevalence of hearing disorder in high-risk neonates treated in a neonatal intensive care unit (NICU). Materials and Methods: This descriptive study was performed on ۱۵۰ neonates treated in the NICU of Besat Hospital in Hamadan, Iran, using a census method. Auditory brainstem response (ABR) and otoacoustic emission (OAE) tests were performed by Labat and HOMOTH devices in Besat Hospital of Hamadan for diagnosis of hearing disorders. Data were analyzed using descriptive statistics and Chi-square test via SPSS ۱۶. Results: In this paper, ۶۳.۳% of studied participants were male and ۳۶.۷% were female. Also, ۴.۷% of participants had mild to severe hearing disorder, and ۳.۳% had moderately-severe hearing loss. There was a statistically significant relationship between age at admission, hearing loss in both ears, and oxygen demand with hearing-impaired participants (ABR test). Conclusion: Considering the presence of ۴.۷% of hearing-impaired neonates (ABR test) in this study, it is necessary to design and implement a comprehensive hearing screening for high-risk neonates in terms of hearing disorders.کلیدواژه ها
Auditory brainstem response, Neonate, Otoacoustic emission, Screeningاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.