Comparison of IOL Master Keratometry with Pentacam Keratometry for Intraocular Lens Power Calculation in Normal Corneas

سال انتشار: 1393
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 193

فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_ZUMS-22-93_001

تاریخ نمایه سازی: 11 اردیبهشت 1400

چکیده مقاله:

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained with the automated (IOL Master) and Scheimpflug keratometer. Scheimpflug readings obtained from simulated K (SIMK) and Holladay equivalent K (EKR) were analysed. Specific formula for a defined intraocular lens was considered according to the IOL Master, Pentacam SIMK and EKR data. Results: ۱۰۰ eyes undergoing PRK were evaluated. The mean age of patients was ۲۷ ± ۴.۳ year old. The mean corneal power by IOL Master, SIMK and the EKR was ۴۴.۵۲ D ± ۱.۵۴, ۴۴.۰۸ D ± ۱.۴۶ and ۴۴.۲۵ D ± ۱.۴۸, respectively. The mean intraocular lens power by these three machines was ۱۷.۱۵ D ± ۲.۱۴ and ۱۷.۶D ± ۲.۲ and ۱۷.۵۳ D ± ۲.۱۴, respectively. There was a statistically significant correlation between IOL Master and SIMK and EKR corneal power and intraocular lens power calculated by the three aforementioned techniques (P < ۰.۰۰۱). There was a statistically significant difference between mean corneal power by IOL Master, SIMK and EKR and intraocular lens power calculated by IOL Master, SIMK and EKR. (P < ۰.۰۰۱) Conclusion: Despite the high correlation between the mean corneal power of automated keratometry, SIMK and EKR, also indicated a high correlation between intraocular lens power calculated by automated keratometry, SIMK and EKR. There was a statistically significant difference between them and the values were not interchangeable. References ۱- Elie Saad, Maya C, Shammas H, John Shammas. Scheimpflug corneal power measurements for intraocular lens power calculation in cataract surgery. Am J Ophthalmol. ۲۰۱۳ ۱۵۶: ۴۶۰-۶۷. ۲- J Santodomingo-Rubido, EAH Mallen, B Gilmartin, JS Wolffsohn. A new non-contact optical device for ocular biometry. Br J Ophthalmol. ۲۰۰۲ ۸۶: ۴۵۸-۶۲. ۳- Olsen T. Improved accuracy of intraocular lens power calculation with Zeiss IOLMaster. Acta Ophthalmol Scand. ۲۰۰۷ ۸۵: ۸۴-۸۷. ۴- Richard J Symes, MRCOphth, Paul G. Ursell, FRC Ophth. Automated keratometry in routine cataract surgery: comparison of scheimpflugand conventional values. J Cataract Refract Surg. ۲۰۱۱ ۳۷: ۲۹۵-۳۰۱. ۵- Borasio E, Stevens J, Smith GT. Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg. ۲۰۰۶ ۳۲: ۲۰۰۴-۱۴. ۶- Kawamorita T, Uozato H, Kamiya K, et al. Repeatability, reproducibility, and agreement characteristics of rotating scheimpflug photography and scanning-slit corneal topography for corneal power measurement. J Cataract Refract Surg. ۲۰۰۹ ۳۵: ۱۲۷-۳۳. ۷- Visser N, Berendschot T, Verbakel F, Brabander P, Nuijts R. Comparability and repeatability of corneal astigmatism measurements using different measurement technologies. J Cataract Refract Surg. ۲۰۱۲ ۳۸: ۱۷۶۴-۷۰. ۸- Richard J, Symes MR, Miranda J, Say MS, Paul G, Ursell FR. Scheimpflugkeratometry versus conventional automated keratometry in routine cataract surgery. J Cataract Refract Surg. ۲۰۱۰ ۳۶: ۱۱۰۷-۱۴. ۹- Neuhann T. Pentacam system’s overview: understanding its benefits. Highlights of Ophthalmology. ۲۰۰۷ ۳۵: ۱-۳. ۱۰- Woodmass J, Rocha G. A comparison of scheimpflug imaging simulated and holladay equivalent keratometry values with partial coherence interferometry keratometry measurements in phakic eyes. Can J Ophthalmol. ۲۰۰۹ ۴۴: ۷۰۰-۴. ۱۱- Giacomo Savini, Piero Barboni, Michele Carbonelli, Kenneth J. Accuracy of scheimpflug corneal power measurements for intraocular lens power calculation. J Cataract Refract Surg. ۲۰۰۹ ۳۵: ۱۱۹۳-۹۷. ۱۲- Barkana Y, Gerber Y, Avni I, Zadoc D. Comparison of different techniques of anterior chamber depth and keratometric measurements. Am J Ophthalmol. ۲۰۰۷ ۱۴۳: ۴۸-۵۳. ۱۳- Shirayama M, Wang L, Weikert MP, Koch DD. Comparison of corneal powers obtained from ۴ different devices. Am J Ophthalmol. ۲۰۰۹ ۱۴۸: ۵۲۸-۳۵. ۱۴- Fledelius HC, Stubgaard M. Changes in refraction and corneal curvature during growth and adult life. A cross-sectional study. Acta Ophthalmol. ۱۹۸۶ ۶۴: ۴۸۷-۹۱. ۱۵- Lam AK, Douthwaite WA. The ageing effect on the central posterior corneal radius. Ophthalmic Physiol Opt. ۲۰۰۰ ۲۰: ۶۳-۶۹.

نویسندگان

زهرا دهنوی

Dept. of Optometry, Rehabilitation School, Iran University of Medical Sciences, Iran

ابراهیم جعفر زاده

Dept. of Optometry, Rehabilitation School, Iran University of Medical Sciences, Iran

علی میرزاجانی

Dept. of Optometry, Rehabilitation School, Iran University of Medical Sciences, Iran

محمود جباروند بهروز

Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran

مهدی خباز خوب

School of Public Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran