Analysis of physical dose enhancement in nano-scale for nanoparticle-based radiation therapy: a Cluster and endothelial cell model
محل انتشار: مجله علوم نانو، دوره: 8، شماره: 1
سال انتشار: 1400
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 308
فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_NAMJ-8-1_004
تاریخ نمایه سازی: 6 اردیبهشت 1400
چکیده مقاله:
Objective(s): One major difficulty of conventional radiotherapy is the lack of selectivity between the tumor and the organs at risk. In nanoparticle aided radiotherapy, heavy elements are present at higher concentrations in the tumor than normal tissues. This study aimed to model the characteristics of secondary electrons generated from the interaction of clusters comprised of five different nanoparticles including Gold, Gadolinium, Iridium, Bismuth, and Hafnium atoms with low energy x-rays (similar to brachytherapy sources in terms of energy) as a function of nanoparticle size and beam energy. Materials and Methods: To better evaluate the contributions of secondary electrons in energy deposition, and also to develop a framework in analyzing further measurements in the future, we attempted to enhance and promote existing mathematical models for energy deposition in endothelial cells by nanoparticle-enhanced radiotherapy. Also, the MCNPX Monte Carlo code was used to model the identical geometry and the dose enhancement factor was calculated for all types of simulated nano-clusters.Results: Our results showed that for our model consist of a nano-cluster and an endothelial cell the DEF significantly depends on the energy of photons and L- and K-edge binding energy of the atoms inside the nano-cluster. However, for Gd at the energy ۶۰ keV, a higher dose enhancement factor was seen.Conclusion: It can be concluded that the mathematical model considers the DEF variation with photon energy and the effect of NP type is considered in DEF calculations. However, the MC method has indicated very high sensitivity to photon energy, and NP type compared to the mathematical method.
کلیدواژه ها:
نویسندگان
Elham Mansouri
Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
Asghar Mesbahi
Molecular Medicine Research center, Tabriz University of Medical Sciences, Tabriz, Iran
Parivar Yazdani
Molecular Medicine Research center, Tabriz University of Medical Sciences, Tabriz, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :