Calculation of dose uniformity ratio in irradiation cell of GC-220 using analytical method based on multipole moment expansion
- سال انتشار: 1399
- محل انتشار: فصلنامه فیزیک و مهندسی پرتو، دوره: 1، شماره: 1
- کد COI اختصاصی: JR_RPE-1-1_005
- زبان مقاله: انگلیسی
- تعداد مشاهده: 173
نویسندگان
Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, PO Box ۱۱۳۶۵-۳۴۸۶, Tehran, Iran
Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, PO Box ۱۱۳۶۵-۳۴۸۶, Tehran, Iran
Physics and Accelerators Research School, Nuclear Science and Technology Research Institute, AEOI, PO Box ۱۱۳۶۵-۳۴۸۶, Tehran, Iran
چکیده
In this paper, dose uniformity ratio in irradiation cell of GC-220 is specifiedutilizing an analytical method based on the multipole moment expansion. In this method, the values of monople, dipole and quadrupole moments for source arrangements of GC-220 are calculated by numerical integrating. Appling these values, the dose uniformity ratio in the irradiation cell of GC-220 is calculated equal to 1.92. Monte Carlo simulation is applied to validate calculations. There is a relative difference about 12% between the results obtained from the analytical calculation and Monte Carlo simulation, which confirm the used method. In comparison with Monte Carlo methods, this method is not time consuming, so, this method can be used for the conceptual designing and the source load planning of irradiators.کلیدواژه ها
Dose Uniformity Ratio, Mutipole Moment Expansion, Monte Carlo Method, Gamma Cell 220, Source Load Planningاطلاعات بیشتر در مورد COI