Application of DNA flow cytometry for detecting ploidy level of tetraploid rainbow trout (Oncorhynchus mykiss)

  • سال انتشار: 1399
  • محل انتشار: چهارمین کنگره بین المللی تحقیقات شیلات و آبزیان
  • کد COI اختصاصی: ICFAR04_177
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 380
دانلود فایل این مقاله

نویسندگان

H Gandomkar

Shahid Motahary Cold-water Fishes Genetic and Breeding Research Center, Iranian Fisheries Sciences Research Institute, Agricultural Research, Education and Extension Organization (AREEO), Yasouj, Iran

S Nazari

Shahid Motahary Cold-water Fishes Genetic and Breeding Research Center, Iranian Fisheries Sciences Research Institute, Agricultural Research, Education and Extension Organization (AREEO), Yasouj, Iran

A Hosseini

Shahid Motahary Cold-water Fishes Genetic and Breeding Research Center, Iranian Fisheries Sciences Research Institute, Agricultural Research, Education and Extension Organization (AREEO), Yasouj, Iran

A Rastian Nasab

Shahid Motahary Cold-water Fishes Genetic and Breeding Research Center, Iranian Fisheries Sciences Research Institute, Agricultural Research, Education and Extension Organization (AREEO), Yasouj, Iran

چکیده

Tetraploidization of rainbow trout (Oncorhynchus mikiss) was induced by hyperthermia and designed in three treatments (28ºC for 10, 12 and 14 min), 7 h after fertilization. Immature fishes were anaesthetised using standard method in tank (Table 1). Blood samples were collected by caudal venipuncture using 2 mL syringes fitted with 0.5 x 35 mm (25 gauge) needles (Sima, Iran) pre-dosed with heparin (Caspian Tamin, Iran). Blood samples subjected to various conditions, were analysed by FC. Methodology was adapted from established protocols for human blood FC analysis, but modified as required due to the nucleated nature of fish erythrocytes. Blood sample evaluations by FC were performed in surface-deactivated polypropylene tubes to minimize cell-tube adhesion and associated quantitation error. Five millilitre 12 x 75 mm polypropylene Falcon tubes (Maxwell, Italy) were filled with a 4% solution of bovine serum albumin (BSA; Sigma, USA) in PBS and stored overnight at 4°C (Lecommandeur et al. 1994). Prior to use, the tubes were emptied and centrifuged at 2000 rpm for 5 min. For each treatment, we also measured the size of erythrocytes and genome size. Genome size was positively correlated with erythrocyte nucleus size and chromosome number when using PI as the fluorescent dye. This work provides new knowledge on Oncorhynchus mykiss genetics/genomics, important for future research in basic cellular/molecular mechanisms and for the development of molecular techniques in this species. However, further investigation is required to obtain a high percent tetraploid Rainbow trout populations.

کلیدواژه ها

Aquaculture, Flow cytometry, Genome size, Ploidy determination

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.