Design and Simulation of Air-Solar Preheating Unit: An Improved Design of a Flat Plate Solar Collector

  • سال انتشار: 1399
  • محل انتشار: فصلنامه انرژی و محیط زیست ایران (ایرانیکا)، دوره: 11، شماره: 2
  • کد COI اختصاصی: JR_IJEE-11-2_002
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 235
دانلود فایل این مقاله

نویسندگان

S. N. Nnamchi

Department of Mechanical Engineering, School of Engineering and Applied Sciences, Kampala International University, Kampala, Uganda

O. A. Nnamchi

Department of Agricultural Engineering and Bio Resources, Michael Okpara University of Agriculture, Umuahia, Nigeria

E. O. Sangotayo

Department of Mechanical Engineering, School of Engineering and Applied Sciences, Kampala International University, Kampala, Uganda

S. A. Ismael

Department of Mechanical Engineering, School of Engineering and Applied Sciences, Kampala International University, Kampala, Uganda

چکیده

The design of a flat-plate solar collector (FPSC) is accomplished by multiple input multiple output (MIMO) design technique. The design variables (absorber, fluid and glass temperatures; length, width, height of the FPSC) were the unknown variables in the commensurate thermal balance equations based on; component, overall and yardstick thermal balance on the FPSC. Then, simulator matrices were setup comprising of coefficient and column matrices of design functions. The elements of the coefficient matrix were the partial derivatives of the design functions with respect to the design variables. Besides the convective and radiative heat transfer coefficients were function of the design variables. The initial values of the design variables (307K, 334.5K, 368K, 2 m, 1 m, and 0.045m, respectively) were set, at the seventh iteration, the output variables (306.9K, 339.15K, 368.1K, 2.01m, 1.005m, 0.04m, respectively) merged as the design functions ® 0 with insignificant change in the design variables. The output results were used to simulate FPSC, to track its responses to changes in the physical conditions, the stimulation revealed some constraints in the design of the FPSC, which is vital information for the overall optimization of the FPSC. The design yardsticks; the thermal efficiency (0.76) and the effectiveness (0.4) are quite pragmatic. This shows that MIMO technique to thermal system design is effective as convergence among the design variables was sought. Moreover, MIMO considered all thermal losses instead of basing the yardsticks on top loss overall transfer coefficient alone; thus, neglecting sidewalls and base losses. Moreover, the advent of connecting box prepares the preheating unit for high temperature drying (> 150 oC) on integration with a reheating unit.

کلیدواژه ها

Air Solar Preheating Unit, Efficiency, Multiple Input Output Design, Optimum Design, Simulation, Solar energy

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.