CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

An Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls High Schools in Arak, Iran)

عنوان مقاله: An Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls High Schools in Arak, Iran)
شناسه ملی مقاله: JR_IJAUD-10-2_003
منتشر شده در شماره 2 دوره 10 فصل در سال 1399
مشخصات نویسندگان مقاله:

Azin Velashjerdi Farahani - M.A., Shahid Beheshti University,School of Architecture and Urban Design, Shahid Beheshti University,
Mansoureh Tahbaz - Associate Professor, Shahid Beheshti University, School of Architecture, Department of Cons truction, Tehran, Iran
Shahram Delfani - Associate professor, Road, Housing and Urban Development Research Center (BHRC), Tehran, Iran.

خلاصه مقاله:
As s tudents spend one-third of their time at school, their health, comfort, and productivity are mos tly influenced by thermal condition and indoor air quality of classrooms. Regarding that manual window-opening is a common way for providing fresh air in classes and s tudents aren t allowed to change their uniform, position or control the windows during the lesson hours, providing thermal comfort in winters may cause a lack of fresh air and therefore, dissatisfaction. This article is trying to evaluate the indoor air quality, and thermal condition of the classrooms, in two typical classrooms for 15-16-year-old girls in Arak, Iran. The overall s tudy objective is to compare indoor microclimate measured parameters, with (1) s tudents subjective judgment, collected through a ques tionnaire, and (2) s tandards and to inves tigate the effects of microclimate on the indoor environmental condition of classrooms. According to the results, the thermal sensation of the students depends on their clothing rate and their understanding of the thermal state. In contrast, their thermal satisfaction is affected by the amount of fresh air provided. In winter, because of closed windows, students are mostly dissatisfied with the air quality and, therefore, thermal comfort, while in spring that the indoor environmental conditions meet the standards; the students feel satisfied with the conditions. The results of this research show that the indoor environment of the classrooms is mainly influenced by internal loads; consequently, its thermal condition is not a defining parameter.

کلمات کلیدی:
Indoor air quality, Thermal Comfort, educational spaces, Natural ventilation

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1029911/