SEISMIC PERFORMANCE OF FACADE MASS ISOLATION SYSTEM IN TALL BUILDINGS
- سال انتشار: 1398
- محل انتشار: هشتمین کنفرانس بین المللی زلزله شناسی و مهندسی زلزله
- کد COI اختصاصی: SEE08_156
- زبان مقاله: انگلیسی
- تعداد مشاهده: 591
نویسندگان
Ph.D. Student, Department of Structural Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
Associate Professor, Department of Structural Engineering, IIEES, Tehran, Iran
Assistant Professor, Department of Structural Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
چکیده
Today, in addition to the form and appearance of a building, facades also play a key role in improving the performance and comfort of residents. Among the façades used in high-rise buildings, recently, double skin façade (DSF) system have been considered. A DSF system consists of two skin layers of glasses with a cavity between the skins. Glazing facades are widely used in outer skin of DSF, due to a series of aesthetic, thermal, lightening aspects. From a structural point of view, facades in tall structures represent a critical component for buildings, due to the brittle behaviour and limited tensile resistance of glass. In this paper, a seismic control method using a DSF system, as a partial mass isolation system, is proposed in order to decrease the level of energy imparted to the main structure during seismic activities. Conventional facade brackets are replaced by isolators and dampers which can isolate facade during earthquake excitation. The feasibility and potential of Facade Mass Isolation (FMI) method to control and mitigate the maximum vibrations and stresses due to seismic events on tall buildings with glazing envelopes is investigated via numerical simulations. A dynamic analysis of the response by time history is used for facade mass isolated structure. The behaviour and performance of structures with DSF and FMI technique are investigated and compared with conventional earthquake-resisting structures. Results show suitable behaviour of structure and also reduction of deformations in facade components.کلیدواژه ها
Partial Mass Isolation, Facade Mass Isolation, Passive Structural Control, Double-Skin Facade, Tall Buildingsمقالات مرتبط جدید
- بررسی اثر پارامترهای محیطی (دما، رطوبت) بر داده های پایش سلامت پل های فولادی
- بررسی تاثیر نوع ساینده بر تاول اسمزی پوشش بر پایه اپوکسی بر سطوح فولای آلیاژ کربن در محیط غوطه ور
- مدل اجزای محدود برای ارزیابی تاثیر خروج از مرکزیت بر ظرفیت ورق های پیوستگی در ستون های H شکل
- ارزیابی احتمالاتی قاب خمشی فولادی بر پایه فولاد St۳۷ و St۵۲ تحت زلزله های نزدیک گسل
- خرابی پیشرونده لرزه ای قاب خمشی فولادی ویژه بلند مرتبه مهاربندی شده در برابر زلزله نزدیک گسل
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.