Production, quality control and imaging of 64Cu-ATSM in healthy rabbits for clinical applications

  • سال انتشار: 1389
  • محل انتشار: مجله پزشکی هسته ای ایران، دوره: 18، شماره: 2
  • کد COI اختصاصی: JR_IRJNM-18-2_004
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 371
دانلود فایل این مقاله

نویسندگان

Yousef Fazaeli

Nuclear Medicine Research Group, Agricultural, Medical and Industrial Research School, Nuclear Science and Technology Research Institute, Atomic Energy organization of Iran,Karaj, Iran

Amir Reza Jalilian

Radiopharmaceutical Research and Development Laboratory, Nuclear Science and Technology Research Institute, Atomic Energy organization of Iran, Tehran, Iran

Mohsen Kamali-Dehghan

Nuclear Medicine Research Group, Agricultural, Medical and Industrial Research School, Nuclear Science and Technology Research Institute, Atomic Energy organization of Iran,Karaj, Iran

Fatemeh Bolourinovin

Nuclear Medicine Research Group, Agricultural, Medical and Industrial Research School, Nuclear Science and Technology Research Institute, Atomic Energy organization of Iran,Karaj, Iran

چکیده

  Introduction: [64Cu]diacetyl-bis(N4-methylthiosemicarbazone) ([64Cu]ATSM) is a well-established hypoxia imaging tracer with reproducible production and significant specifity. In this work the high yield production and quality control as well as imaging studies in healthy rabbits is reported. Methods: Copper-64 produced via the 68Zn(p,an)64Cu nuclear reaction (30 MeV protons at 180 µA) was used for the preparation of [64Cu]diacetyl-bis(N4-methylthiosemicarbazone)([64Cu]ATSM). Followed by quality control and administration to healthy rats as well as healthy rabbits for biodistribution and imaging studies respectively. Results: 64Cu2+ (500 mCi, separation yield> 95%, radionuclide purity> 96%) was used for [64Cu]ATSM production (radiochemical purity> 99%, specific activity of 300 Ci/mmol) followed by administration to healthy rabbits and coincidence imaging demonstrating uptake in liver, kidney and bowel as shown by other reports in various rodents and human. Conclusion: [64Cu]ATSM radiopharmaceutical is produced and now available in large quantities for research and/or clinical trials in the country.

کلیدواژه ها

Radiolabeling, quality control, [64Cu]ATSM, Rabbits, Biodistribution, Coincidence imaging

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.