CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Rapid and simple magnetic solid-phase extraction of bisphenol A from bottled water, baby bottle, and urine samples using green magnetic hydroxyapatite/β-cyclodextrin polymer nanocomposite

عنوان مقاله: Rapid and simple magnetic solid-phase extraction of bisphenol A from bottled water, baby bottle, and urine samples using green magnetic hydroxyapatite/β-cyclodextrin polymer nanocomposite
شناسه ملی مقاله: MRSS05_013
منتشر شده در پنجمین کنگره ملی شیمی و نانو شیمی از پژوهش تا توسعه ملی در سال 1401
مشخصات نویسندگان مقاله:

Niloofar Salehpour - Faculty of Chemistry and Petroleum Sciences, Shahid Beheshti University, G.C., Evin, Tehran, Iran
Mohammareza Bayatloo - Faculty of Chemistry and Petroleum Sciences, Shahid Beheshti University, G.C., Evin, Tehran, Iran
Saeed Nojavan - Faculty of Chemistry and Petroleum Sciences, Shahid Beheshti University, G.C., Evin, Tehran, Iran

خلاصه مقاله:
Bisphenol A (BPA) is a synthetic organic compound widely used as a starting material in plastics synthesis. The high toxicity of BPA has promoted the development of effective analytical methods for its separation and detection in complex samples. Herein, a novel magnetic nanocomposite consisting of hydroxyapatite and β-cyclodextrin polymer (MHAP/β-CDP) was designed and synthesized by a novel and convenient method for magnetic solid-phase extraction (MSPE) of BPA. The adsorption mechanisms of the MHAP/β-CDP toward BPA were mainly based on the hydrophilic interactions and formation of host-guest inclusion complex. The prepared magnetic nanocomposite was characterized by the vibrating-sample magnetometer (VSM), field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD) analysis, and thermogravimetric analysis (TGA). To obtain the best extraction conditions, the extraction parameters were optimized. Under the optimized conditions, MSPE combined with high-performance liquid chromatography-diode array detector (HPLC-DAD) was applied for the determination of BPA in bottled water, baby bottle, and urine samples. The proposed method provided low limits of detection (۰.۰۶ ng mL-۱) and quantification (۰.۱۸ ng mL-۱), good linearity (R۲ = ۰.۹۹۶) in the range of ۰.۵-۱۰۰۰.۰ ng mL-۱, good repeatability (۳.۲-۴.۱%, n = ۴) and reproducibility (۴.۹-۵.۴%, n = ۳ days). Furthermore, satisfactory relative recoveries in the range of ۹۷.۰-۱۰۲.۰% were obtained for quantification of BPA in bottled water, baby bottle, and urine samples.

کلمات کلیدی:
Bisphenol A, Hydroxyapatite, Magnetic solid-phase extraction, Nanocomposite, Urine, β-cyclodextrin polymer

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1496195/